Aims and Objectives:Tibial posterior cruciate ligament (PCL) avulsion fractures require surgical fixation in order to provide primary stability and adequate bone healing. Small fragments are common and comprise the risk to fracturing during screw fixation. Therefore, a suture-bridge configuration was developed to fixate small and multifragment fractures without the need of fragment drilling. The purpose of this study was to analyze the biomechanical properties of the suture-bridge technique compared to a well-established transtibial cortical suspension technique concerning cyclic elongation, stiffness and ultimate failure load. It was hypothesized that the suture bridge technique shows lower cyclic elongation and higher load to failure force compared to a cortical suspension button fixation.
机译:目的和目的:胫骨后交叉韧带(PCL)撕脱骨折需要手术固定,以提供基本的稳定性和足够的骨愈合。小碎片很常见,并且在螺丝固定过程中容易断裂。因此,开发了一种缝桥结构,可固定小碎片和多碎片骨折,而无需进行碎片钻孔。这项研究的目的是分析缝合桥技术的生物力学性能,并与公认的经皮皮质悬吊技术相比较,研究其循环伸长率,刚度和最终破坏载荷。据推测,与皮质悬吊钮固定相比,缝合桥技术显示出较低的循环伸长率和较高的破坏力负荷。