摘要

In intensity‐modulated radiation therapy (IMRT) and volumetric‐modulated arc therapy (VMAT), the use of posterior oblique beams has become common. Beam attenuation by the treatment couch is not negligible when the couch is in the beam portal. In this study, we established the relationship of relative dose vs. beam angle for two Varian 21EX linacs, one equipped with the Exact couch (standard couch) with sliding side support rails, and the other equipped with the Exact image‐guided radiation therapy (IGRT) carbon fiber couch. Measurements were performed using an ion chamber placed at the center of an acrylic cylindrical phantom positioned at the linac isocenter for 6 MV and 18 MV photon beams. Measurements were performed at three different field sizes (3×3,5×5, and 10×10cm2, and were repeated with the phantom positioned at different longitudinal locations on the couches. To evaluate beam attenuation by the standard couch in a clinical setting, two test IMRT plans and two test VMAT plans on the standard couch were delivered. The plans were generated with the sliding rails at the “in” position and delivered with the rails at both “in” and “out” positions. The dose difference to the ion chamber was determined. For oblique fields with 6 MV photons, the standard couch attenuated the radiation beam by up to 26.8%, while the carbon fiber IGRT couch attenuated the beam by up to 4.1%. In the clinical evaluation, the highest dose difference between rails set at the “in” and “out” positions was 2.6% in the IMRT case and 2.1% in the VMAT case. The magnitude of potential dose difference has been quantified and could be used for a quick estimation of dose difference due to couch attenuation in IMRT and VMAT.PACS number: 87.56.‐v
机译:在强度调制放射治疗(IMRT)和体积调制放射治疗(VMAT)中,后斜光束的使用已变得很普遍。当治疗床在射线入口中时,治疗床对射线的衰减不可忽略。在这项研究中,我们建立了两种Varian 21EX直线加速器的相对剂量与光束角的关系,其中一种配备了带有可滑动侧支撑轨的Exact沙发(标准躺椅),而另一种则配备了精确图像引导的放射疗法( IGRT)碳纤维沙发。使用离子室进行测量,该离子室位于6 MV和18 MV光子束的位于直线加速器等中心处的丙烯酸圆柱体模型的中心。在三个不同的字段大小下进行了测量 3 × 3 5 × 5 10 × 10 cm 2 ,然后将幻像放置在躺椅上的不同纵向位置上,然后重复进行此操作。要在临床环境中评估标准躺椅的光束衰减,需要两个IMRT测试计划和两个VMAT测试计划在标准沙发上交付了计划,在滑轨处于“入”位置时生成了计划,并在“入”和“出”位置时都交付了轨道,确定了与离子室的剂量差。在6 MV光子的作用下,标准躺椅可将辐射束衰减高达26.8%,而碳纤维IGRT躺椅可将光束高达4.1%。在临床评估中,在IMRT病例和VMAT病例中,设置在“入”和“出”位置的钢轨之间的最大剂量差为2.6%,而VMAT病例为2.1%。由于IMRT和VMAT中的卧榻衰减,潜在剂量差异的大小已被量化,可用于快速估计剂量差异.PACS编号:87.56.-v

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号