A guarded cylindrical graphite ionization chamber of nominal volume 1000cm3 was designed and fabricated for use as a reference standard for low‐dose rate 137Cs brachytherapy sources. The air kerma calibration coefficient (NK) of this ionization chamber was estimated analytically using Burlin's general cavity theory, as well as by the Monte Carlo simulation and validated experimentally using Amersham CDCS‐J‐type 137Cs reference source. In the analytical method, the NK was calculated for 662 keV gamma rays of 137Cs brachytherapy source. In the Monte Carlo method, the geometry of the measurement setup and physics‐related input data of the 137Cs source and the surrounding material were simulated using the Monte Carlo N‐Particle code. The photon energy fluence was used to arrive at the reference air kerma rate (RAKR) using mass energy absorption coefficient. The energy deposition rates were used to simulate the value of charge rate in the ionization chamber, and the NK was determined. The analytical and Monte Carlo values of NK of the cylindrical graphite ionization chamber for 137Cs brachytherapy source are in agreement within 1.07%. The deviation of analytical and Monte Carlo values from experimental values of NK is 0.36% and 0.72%, respectively. This agreement validates the analytical value, and establishes this chamber as a reference standard for RAKR or AKS measurement of 137Cs brachytherapy sources.PACS numbers: 87.53.Bn, 87.53.Jw, 87.56.bg, 87.55.Qr
机译:标称体积 的防护圆柱形石墨电离室 1000 cm 3 < / math>被设计和制造为用作低剂量率的参考标准 137 Cs 近距离放射治疗来源。空气比释动能校正系数 N K <使用Burlin的一般空腔理论以及蒙特卡罗模拟方法,对该电离室的mo Stretchy =“ false”>) 进行了分析估算,并使用Amersham CDCS‐J‐键入 137 Cs 参考源。在分析方法中, N K : mml =“ http://www.w3.org/1998/Math/MathML” id =“ nlm-math-7”溢出=“ scroll”> 137 Cs 近距离放射治疗源。在蒙特卡洛方法中,测量设置的几何形状和 137 Cs 源和周围材料进行了模拟。使用质量能吸收系数,使用光子能量通量得出参考空气比释动能比(RAKR)。能量沉积速率用于模拟电离室中的电荷速率值,并且 N K 已确定。 N K : mml =“ http://www.w3.org/1998/Math/MathML” id =“ nlm-math-11”溢出=“ scroll”> 近距离放射疗法来源中, 137 Cs 在1.07%之内。分析和蒙特卡洛值与 N K 分别为0.36%和0.72% , 分别。该协议验证了分析值,并将该腔室作为 137 Cs < / mrow> 近距离放射治疗来源。PACS编号:87.53.Bn,87.53.Jw,87.56.bg,87.55.Qr

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号