An experimental investigation on the effect of beam angle optimization on the reduction of beam numbers in IMRT of head and neck tumors

机译:优化束角对减少头颈部肿瘤IMRT中束数影响的实验研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In static intensity‐modulated radiation therapy (IMRT), the fundamental factors that determine the quality of a plan are the number of beams and their angles. The objective of this study is to investigate the effect of beam angle optimization (BAO) on the beam number in IMRT. We used six head and neck cases to carry out the study. Basically the methodology uses a parameter called “Beam Intensity Profile Perturbation Score” (BIPPS) to determine the suitable beam angles in IMRT. We used two set of plans in which one set contains plans with equispaced beam configuration starting from beam numbers 3 to 18, and another set contains plans with optimal beam angles chosen using the in‐house BAO algorithm. We used quadratic dose‐based single criteria objective function as a measure of the quality of a plan. The objective function scores obtained for equispaced beam plans and optimal beam angle plans for six head and neck cases were plotted against the beam numbers in a single graphical plot for effective comparison. It is observed that the optimization of beam angles reduces the beam numbers required to produce clinically acceptable dose distribution in IMRT of head and neck tumors. Especially N0.1 (represents the beam number at which the objective function reaches a value of 0.1) is considerably reduced by beam angle optimization in almost all the cases included in the study. We believe that the experimental findings of this study will be helpful in understanding the interplay between beam angle optimization and beam number selection process in IMRT which, in turn, can be used to improve the performance of BAO algorithms and beam number selection process in IMRT.PACS number: 87.55.de
机译:在静态强度调制放射治疗(IMRT)中,决定计划质量的基本因素是光束数量及其角度。本研究的目的是研究IMRT中光束角优化(BAO)对光束数的影响。我们使用了六个头颈部病例进行了研究。基本上,该方法使用一个称为“光束强度轮廓摄动分数”(BIPPS)的参数来确定IMRT中合适的光束角度。我们使用了两组计划,其中一组包含从3至18号波束开始的等距波束配置计划,另一组包含使用内部BAO算法选择的最佳波束角度的计划。我们使用基于二次剂量的单一标准目标函数来衡量计划的质量。将等间隔波束计划和六个头部和颈部情况的最佳波束角度计划获得的目标函数得分与波束数在单个图形图中进行绘制,以进行有效比较。观察到,束角的优化减少了在头颈部肿瘤的IMRT中产生临床上可接受的剂量分布所需的束数。特别是 N 0.1 (表示目标函数达到0.1的光束数量)被光束角度大大减小了研究中几乎所有情况下的优化。我们相信,这项研究的实验结果将有助于理解IMRT中的光束角度优化与光束数量选择过程之间的相互作用,进而可以用来改善IMRT中的BAO算法和光束数量选择过程的性能。 PACS编号:87.55.de

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号