首页> 美国卫生研究院文献>Journal of Applied Clinical Medical Physics >Dosimetry of gamma chamber blood irradiator using PAGAT gel dosimeter and Monte Carlo simulations
【2h】

Dosimetry of gamma chamber blood irradiator using PAGAT gel dosimeter and Monte Carlo simulations

机译:使用PAGAT凝胶剂量计和Monte Carlo模拟进行伽马腔血液辐照器剂量测定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Currently, the use of blood irradiation for inactivating pathogenic microbes in infected blood products and preventing graft‐versus‐host disease (GVHD) in immune suppressed patients is greater than ever before. In these systems, dose distribution and uniformity are two important concepts that should be checked. In this study, dosimetry of the gamma chamber blood irradiator model Gammacell 3000 Elan was performed by several dosimeter methods including thermoluminescence dosimeters (TLD), PAGAT gel dosimetry, and Monte Carlo simulations using MCNP4C code. The gel dosimeter was put inside a glass phantom and the TL dosimeters were placed on its surface, and the phantom was then irradiated for 5 min and 27 sec. The dose values at each point inside the vials were obtained from the magnetic resonance imaging of the phantom. For Monte Carlo simulations, all components of the irradiator were simulated and the dose values in a fine cubical lattice were calculated using tally F6. This study shows that PAGAT gel dosimetry results are in close agreement with the results of TL dosimetry, Monte Carlo simulations, and the results given by the vendor, and the percentage difference between the different methods is less than 4% at different points inside the phantom. According to the results obtained in this study, PAGAT gel dosimetry is a reliable method for dosimetry of the blood irradiator. The major advantage of this kind of dosimetry is that it is capable of 3D dose calculation.PACS number: 87.53.Bn
机译:目前,在免疫抑制患者中,使用血液辐照灭活感染的血液制品中的病原微生物并预防移植物抗宿主病(GVHD)的用途比以往任何时候都多。在这些系统中,剂量分布和均匀性是应检查的两个重要概念。在这项研究中,伽马室血液辐照器模型Gammacell 3000 Elan的剂量测定是通过几种剂量计方法进行的,包括热发光剂量计(TLD),PAGAT凝胶剂量测定法和使用MCNP4C代码的蒙特卡洛模拟。将凝胶剂量计放在玻璃体模内,将TL剂量计放在其表面上,然后将体模照射5分钟和27秒。小瓶内每个点的剂量值是从体模的磁共振成像获得的。对于Monte Carlo模拟,模拟了辐照器的所有组件,并使用计数F6计算了精细立方晶格中的剂量值。这项研究表明,PAGAT凝胶剂量测定结果与TL剂量测定法,蒙特卡洛模拟以及供应商给出的结果非常吻合,并且在幻像内部的不同点之间,不同方法之间的百分比差异小于4% 。根据本研究获得的结果,PAGAT凝胶剂量测定法是一种可靠的血液辐照器剂量测定法。这种剂量学的主要优点是它能够进行3D剂量计算。PACS编号:87.53.Bn

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号