Larynx may alternatively serve as a target or organs at risk (OAR) in head and neck cancer (HNC) image‐guided radiotherapy (IGRT). The objective of this study was to estimate IGRT parameters required for larynx positional error independent of isocentric alignment and suggest population‐based compensatory margins. Ten HNC patients receiving radiotherapy (RT) with daily CT on‐rails imaging were assessed. Seven landmark points were placed on each daily scan. Taking the most superior‐anterior point of the C5 vertebra as a reference isocenter for each scan, residual displacement vectors to the other six points were calculated postisocentric alignment. Subsequently, using the first scan as a reference, the magnitude of vector differences for all six points for all scans over the course of treatment was calculated. Residual systematic and random error and the necessary compensatory CTV‐to‐PTV and OAR‐to‐PRV margins were calculated, using both observational cohort data and a bootstrap‐resampled population estimator. The grand mean displacements for all anatomical points was 5.07 mm, with mean systematic error of 1.1 mm and mean random setup error of 2.63 mm, while bootstrapped POIs grand mean displacement was 5.09 mm, with mean systematic error of 1.23 mm and mean random setup error of 2.61 mm. Required margin for CTV‐PTV expansion was 4.6 mm for all cohort points, while the bootstrap estimator of the equivalent margin was 4.9 mm. The calculated OAR‐to‐PRV expansion for the observed residual setup error was 2.7 mm and bootstrap estimated expansion of 2.9 mm. We conclude that the interfractional larynx setup error is a significant source of RT setup/delivery error in HNC, both when the larynx is considered as a CTV or OAR. We estimate the need for a uniform expansion of 5 mm to compensate for setup error if the larynx is a target, or 3 mm if the larynx is an OAR, when using a nonlaryngeal bony isocenter.PACS numbers: 87.55.D‐, 87.55.Qr
机译:喉部也可作为头颈癌(HNC)图像引导放疗(IGRT)的靶标或高危器官(OAR)。这项研究的目的是估计与等中心线无关的喉部位置误差所需的IGRT参数,并提出基于人群的代偿性余量。评估了10例接受放射治疗(RT)和每日CT轨道成像的HNC患者。每天进行一次扫描,放置七个标志性点。每次扫描均以C5椎骨的最上前点作为参考等中心点,计算出等中心线对准后其他六个点的残余位移矢量。随后,以第一次扫描为参考,计算在整个治疗过程中所有扫描的所有六个点的矢量差的大小。使用观察性队列数据和自举重采样人口估计量,计算了残留的系统误差和随机误差,以及必要的补偿性CTV至PTV和OAR至PRV的余量。所有解剖​​点的平均位移为5.07 mm,平均系统误差为1.1 mm,平均随机设置误差为2.63 mm,而自举POI的平均位移为5.09 mm,平均系统误差为1.23 mm,平均随机设置误差2.61毫米对于所有同类人群,CTV-PTV扩展所需的余量为4.6 mm,而等效余量的自举估计为4.9 mm。对于观察到的残留设置误差,计算出的OAR到PRV膨胀为2.7 mm,自举估计膨胀为2.9 mm。我们得出的结论是,当将喉部视为CTV或OAR时,HNC中的分形喉部建立错误是RT设立/交付错误的重要来源。如果使用喉头非骨性等角点,我们估计需要5 mm的均匀膨胀以补偿安装误差(如果喉头是目标,如果喉头是OAR则需要3 mm).PACS编号:87.55.D‐,87.55。 Qr