首页> 美国卫生研究院文献>Physiological Reports >Validity and reliability of a field technique for sweat Na+ and K+ analysis during exercise in a hot‐humid environment
【2h】

Validity and reliability of a field technique for sweat Na+ and K+ analysis during exercise in a hot‐humid environment

机译:在炎热潮湿的环境中运动时进行汗液中Na +和K +分析的现场技术的有效性和可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study compared a field versus reference laboratory technique for extracting (syringe vs. centrifuge) and analyzing sweat [Na+] and [K+] (compact Horiba B‐722 and B‐731, HORIBA vs. ion chromatography, HPLC) collected with regional absorbent patches during exercise in a hot‐humid environment. Sweat samples were collected from seven anatomical sites on 30 athletes during 1‐h cycling in a heat chamber (33°C, 67% rh). Ten minutes into exercise, skin was cleaned/dried and two sweat patches were applied per anatomical site. After removal, one patch per site was centrifuged and sweat was analyzed with HORIBA in the heat chamber (CENTRIFUGE HORIBA) versus HPLC (CENTRIFUGE HPLC). Sweat from the second patch per site was extracted using a 5‐mL syringe and analyzed with HORIBA in the heat chamber (SYRINGE HORIBA) versus HPLC (SYRINGE HPLC). CENTRIFUGE HORIBA, SYRINGE HPLC, and SYRINGE HORIBA were highly related to CENTRIFUGE HPLC ([Na+]: ICC = 0.96, 0.94, and 0.93, respectively; [K+]: ICC = 0.87, 0.92, and 0.84, respectively), while mean differences from CENTRIFUGE HPLC were small but usually significant ([Na+]: 4.7 ± 7.9 mEql/L, −2.5 ± 9.3 mEq/L, 4.0 ± 10.9 mEq/L (all P < 0.001), respectively; [K+]: 0.44 ± 0.52 mEq/L (P < 0.001), 0.01 ± 0.49 mEq/L (P = 0.77), 0.50 ± 0.48 mEq/L (P < 0.001), respectively). On the basis of typical error of the measurement results, sweat [Na+] and [K+] obtained with SYRINGE HORIBA falls within ±15.4 mEq/L and ±0.68 mEq/L, respectively, of CENTRIFUGE HPLC 95% of the time. The field (SYRINGE HORIBA) method of extracting and analyzing sweat from regional absorbent patches may be useful in obtaining sweat [Na+] when rapid estimates in a hot‐humid field setting are needed.
机译:这项研究比较了现场实验室和参考实验室的技术(注射器与离心机)提取和分析汗液[Na + ]和[K + ](紧凑型Horiba B-722和B‐731,HORIBA与离子色谱,HPLC)在湿热环境下运动期间使用局部吸收剂贴片收集。在加热室(33°C,67%rh)中进行1小时的骑行过程中,从30位运动员的七个解剖部位收集了汗液样本。运动十分钟后,清洁/干燥皮肤,并在每个解剖部位涂抹两块汗水。去除后,每个部位离心一个贴片,并在加热室中使用HORIBA(CENTRIFUGE HORIBA)与HPLC(CENTRIFUGE HPLC)进行汗液分析。每个部位第二个贴剂的汗液使用5 mL注射器提取,并在加热室中使用HORIBA(SYRINGE HORIBA)与HPLC(SYRINGE HPLC)进行分析。 CENTRIFUGE HORIBA,SYRINGE HPLC和SYRINGE HORIBA与CENTRIFUGE HPLC高度相关([Na + ]:ICC分别为0.96、0.94和0.93; [K + ] :ICC分别为0.87、0.92和0.84),而与CENTRIFUGE HPLC的平均差异很小,但通常很显着([Na + ]:4.7±7.9 mEql / L,-2.5±9.3 mEq / L,分别为4.0±10.9 mEq / L(所有P <0.001); [K + ]:0.44±0.52 mEq / L(P <0.001),0.01±0.49 mEq / L(P = 0.77),0.50±0.48 mEq / L(P <0.001)。根据测量结果的典型误差,用SYRINGE HORIBA获得的汗液[Na + ]和[K + ]落在±15.4 mEq / L和±0.68 mEq之内/ L分别在95%的时间内使用CENTRIFUGE HPLC。当需要在炎热潮湿的环境中进行快速估算时,从区域吸收性贴剂中提取和分析汗液的田间(SYRINGE HORIBA)方法可能有助于获得汗液[Na + ]。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号