摘要

The purpose of this study was to determine interfractional variation of the centroid position and volume of internal target volume (ITV) during stereotactic body radiation therapy (SBRT) of lung cancer. From January 2014 to August 2014, a total of 32 patients with 37 primary or metastatic lung tumors were enrolled in our study. All patients received SBRT treatment in 4–5 fractions to a median dose of 48 Gy. Both 3D CT and 4D CT scans were used for radiotherapy treatment planning. 3D CBCT was acquired prior to treatment delivery to verify patient positioning. A total of 163 3D CBCT images were available for evaluation. 3D CBCT scans acquired for verification were registered with simulation CT scans. The ITVs were contoured on all verification 3D CBCT scans and compared to the initial gross target volume (GTV) or ITV in treatment planning system. GTV was based on 3D CT while ITV was based on both 3D CT and 4D CT. To assess the interfractional variation of ITV centroid position, we used vertebrae body adjacent to the tumor as reference point when performing the registration procedure. To eliminate the effect of time on tumor volume between simulation CT scan and the first fraction, the interfractional variation of ITV was evaluated from the first fraction to the last fraction. The overall 3D vector shift was 4.4 ± 2.5 mm (range: 0.4 − 13.8 mm). The interfractional variation of ITV centroid position in superior‐inferior, anterior‐posterior, and left‐right directions were −0.7 ± 2.7 mm, −1.4 ± 3.4 mm, and −0.5 ± 2.2 mm, respectively. No significant difference was observed between three directions (p = 0.147). Large interfractional variations ( ≥ 5 mm) were observed in 12 fractions (9.3%) in superior‐inferior direction, 24 fractions (18.6%) in anterior‐posterior direction, and 5 fractions (3.9%) in left‐right direction. No time trend of tumor volume change measured in 3D CBCT was detected during four fractions (p = 0.074). A significant (p = 0.010) time trend was detected when evaluating the time trend of ITV change during 5 fractions and diameter was found to be significantly correlated with the ITV change (p=0.000). ITV did not show significant regression during SBRT treatment, but interfractional variation in the ITV centroid position was observed, especially in anterior‐posterior direction. An isotropic margin of 7 mm around ITV might be necessary for adequate coverage of interfractional variation of ITV centroid position, but only in case no soft tissue‐based setup is performed during SBRT treatment.PACS number(s): 87.55.dk
机译:这项研究的目的是确定肺癌的立体定向放射治疗(SBRT)过程中质心位置和内部目标体积(ITV)体积的分数变化。从2014年1月至2014年8月,我们纳入了32例患有37例原发性或转移性肺肿瘤的患者。所有患者均接受SBRT治疗4-5次,中位剂量为48 Gy。 3D CT和4D CT扫描均用于放射疗法治疗计划。在进行治疗之前已获取3D CBCT以验证患者的位置。共有163张3D CBCT图像可供评估。为验证而获得的3D CBCT扫描与模拟CT扫描配准。在所有验证的3D CBCT扫描中绘制ITV轮廓,并与治疗计划系统中的初始总目标量(GTV)或ITV进行比较。 GTV基于3D CT,而ITV同时基于3D CT和4D CT。为了评估ITV质心位置的分数变化,在执行配准程序时,我们以邻近肿瘤的椎体为参考点。为了消除时间对模拟CT扫描和第一个分数之间的肿瘤体积的影响,从第一个分数到最后一个分数评估了ITV的分数变化。整体3D矢量偏移为4.4±2.5mm(范围:0.4−13.8mm)。 ITV质心位置在上下,前后,左右方向的分数变化分别为-0.7±2.7 mm,-1.4±3.4 mm和-0.5±2.2 mm。在三个方向之间未观察到显着差异(p = 0.147)。在上下方向上观察到12个分数(9.3%),在前后方向上观察到24个分数(18.6%),在左右方向上观察到5个分数(3.9%)时,观察到较大的分数变化(≥5 mm)。在四个部分中未检测到在3D CBCT中测量到的肿瘤体积变化的时间趋势(p = 0.074)。在评估5个分数期间的ITV变化的时间趋势时,发现了明显的(p = 0.010)时间趋势,并且发现直径与ITV变化显着相关( p = 0.000 )。在SBRT治疗期间,ITV并未显示出明显的消退,但观察到ITV质心位置的分数变化,尤其是前后方向。为了充分覆盖ITV质心位置的分数变化,可能需要在ITV周围有7 mm的各向同性边缘,但前提是在SBRT治疗期间未进行基于软组织的设置的情况下.PACS编号:87.55.dk

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号