首页> 美国卫生研究院文献>Journal of Applied Clinical Medical Physics >Evaluation of dose‐area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria
【2h】

Evaluation of dose‐area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria

机译:评估普通放射线照相检查的剂量面积乘积以在尼日利亚西南部建立初步诊断参考水平(PDRL)

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In Nigeria, a large number of radiographic examinations are conducted yearly for various diagnostic purposes. However, most examinations carried out do not have records of doses received by the patients, and the employed exposure parameters used are not documented; therefore, adequate radiation dose management is hindered. The aim of the present study was to estimate the dose‐area product (DAP) of patients examined in Nigeria, and to propose regional reference dose levels for nine common examinations (chest PA, abdomen AP, pelvis AP, lumbar AP, skull AP, leg AP, knee AP, hand AP, and thigh AP) undertaken in Nigeria. Measurement of entrance surface dose (ESD) was carried out using thermoluminescent dosimeter (TLD). Measured ESDS were converted into DAP using the beam area of patients in 12 purposely selected hospitals. Results of the study show that the maximum/minimum ratio ranged from 3 for thigh AP to 57 in abdomen AP. The range of determined mean and 75th percentile DAPs were 0.18–17.16, and 0.25–28.59 Gy cm2, respectively. Data available for comparison show that 75th percentile DAPs in this study (in chest PA, abdomen AP, pelvis AP, lumbar AP) are higher than NRPB‐HPE reference values. The DAP in this study is higher by factor of 31.4 (chest PA), 9.9 (abdomen AP), 2.2 (pelvis AP), and 2.1 (lumbar AP) than NRPB‐HPE values. The relative higher dose found in this study shows nonoptimization of practice in Nigeria. It is expected that regular dose auditing and dose optimization implementation in Nigeria would lead to lower DAP value, especially in abdomen AP. The 75th percentile DAP distribution reported in this study could be taken as regional diagnostic reference level in the Southwestern Nigeria; however, a more extensive nationwide dose survey is required to establish national reference dose.PACS number(s): 87.53.Bn, 87.59.B
机译:在尼日利亚,出于各种诊断目的,每年都要进行大量的射线照相检查。但是,大多数检查都没有患者接受剂量的记录,所使用的暴露参数也没有记录。因此,妨碍了适当的放射线剂量管理。本研究的目的是评估尼日利亚接受检查的患者的剂量面积积(DAP),并为九种常见检查(胸部PA,腹部AP,骨盆AP,腰椎AP,颅骨AP,腿AP,膝盖AP,手AP和大腿AP)在尼日利亚进行。使用热发光剂量计(TLD)进行入射表面剂量(ESD)的测量。使用12家故意选择的医院中患者的束流面积,将测得的ESDS转换为DAP。研究结果表明,最大/最小比率范围从大腿AP的3到腹部AP的57。确定的平均DAP和第75个百分位数DAP的范围分别为0.18–17.16和0.25–28.59 Gy cm 2 。可用于比较的数据表明,该研究中第75个百分位DAP(胸部PA,腹部AP,骨盆AP,腰椎AP)高于NRPB-HPE参考值。本研究中的DAP比NRPB-HPE值高31.4倍(胸部PA),9.9倍(腹部AP),2.2倍(骨盆AP)和2.1倍(腰腹AP)。在这项研究中发现的相对较高的剂量表明在尼日利亚实践并非最佳。预计在尼日利亚定期进行剂量审核和剂量优化将导致DAP值降低,尤其是在腹部AP中。本研究报告的第75个百分位DAP分布可作为尼日利亚西南地区的区域诊断参考水平。但是,需要进行更广泛的全国剂量调查才能确定国家参考剂量。PACS编号:87.53.Bn,87.59.B

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号