Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult's common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (CTDI_(vol.,W)) and dose length product (DLP) of four common CT examinations including head, head sinus, chest, abdomen and pelvis were measured for 8 different CT scanners using standard head and body phantoms. The image quality of acquired scan images were assessed according to European Commission (EC) image quality criteria guidelines. Results: The mean measured CTDI_W for head base; head cerebrum, head sinus, chest and abdomen-pelvis were 71.8, 29.7, 35.8, 9.8 and 12.9 mGy, respectively. The DLP for head, head sinus, chest and abdomen -pelvis were 500, 37, 225 and 482 mGy.cm. The results of our study were shown more patient doses in terms of DLP for head sinus in compare with other studies while CTDl_w values for head base and sinus were higher than EC measurements. Conclusion: The great variations of CTDI_W and DLP observed among hospitals and relatively high values of DLP in some centers are evidence that radiation doses of patients from CT examinations is not fully optimized. It was concluded that future studies of continues optimization to minimize the dose without affecting image quality are needed.
机译:背景:由于每天进行的CT检查次数越来越多,计算机断层扫描(CT)产生的放射剂量正在增加。这项研究的目的是评估和评估成人普通CT检查的患者放射剂量,以得出普通CT检查的局部诊断指导水平。材料和方法:用8种不同的CT扫描仪测量了四种常见的CT检查(包括头,头窦,胸部,腹部和骨盆)的体积和加权计算机断层扫描剂量指数(CTDI_(vol。,W))和剂量长度乘积(DLP)。使用标准的头部和身体幻影。根据欧洲委员会(EC)图像质量标准准则评估获取的扫描图像的图像质量。结果:头基的平均测得的CTDI_W;头部大脑,鼻窦,胸部和腹部骨盆分别为71.8、29.7、35.8、9.8和12.9 mGy。头,头窦,胸部和腹部骨盆的DLP为500、37、225和482mGy.cm。我们的研究结果显示,与其他研究相比,头部窦的DLP剂量更高,而头部和窦的CTDl_w值高于EC测量值。结论:医院之间观察到的CTDI_W和DLP的巨大差异以及某些中心的DLP值相对较高,这表明CT检查患者的放射剂量并未得到充分优化。得出的结论是,需要继续优化以最小化剂量而不影响图像质量的未来研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号