首页> 美国卫生研究院文献>JARO: Journal of the Association for Research in Otolaryngology >The Intelligibility of Interrupted Speech: Cochlear Implant Users and Normal Hearing Listeners
【2h】

The Intelligibility of Interrupted Speech: Cochlear Implant Users and Normal Hearing Listeners

机译:语音中断的可理解性:人工耳蜗使用者和听力正常的听众

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Compared with normal-hearing listeners, cochlear implant (CI) users display a loss of intelligibility of speech interrupted by silence or noise, possibly due to reduced ability to integrate and restore speech glimpses across silence or noise intervals. The present study was conducted to establish the extent of the deficit typical CI users have in understanding interrupted high-context sentences as a function of a range of interruption rates (1.5 to 24 Hz) and duty cycles (50 and 75 %). Further, factors such as reduced signal quality of CI signal transmission and advanced age, as well as potentially lower speech intelligibility of CI users even in the lack of interruption manipulation, were explored by presenting young, as well as age-matched, normal-hearing (NH) listeners with full-spectrum and vocoded speech (eight-channel and speech intelligibility baseline performance matched). While the actual CI users had more difficulties in understanding interrupted speech and taking advantage of faster interruption rates and increased duty cycle than the eight-channel noise-band vocoded listeners, their performance was similar to the matched noise-band vocoded listeners. These results suggest that while loss of spectro-temporal resolution indeed plays an important role in reduced intelligibility of interrupted speech, these factors alone cannot entirely explain the deficit. Other factors associated with real CIs, such as aging or failure in transmission of essential speech cues, seem to additionally contribute to poor intelligibility of interrupted speech.
机译:与正常听力的听众相比,人工耳蜗(CI)的用户表现出的语音清晰度由于静音或噪音而中断,这可能是由于在静音或噪音间隔内整合和恢复语音提示的能力降低所致。进行本研究是为了确定典型CI用户在理解中断的高语境句子方面的不足程度是中断率范围(1.5至24Hz)和占空比(50%和75%)的函数。此外,通过展示年轻的,年龄匹配的,正常听力的人,探索了诸如CI信号传输的信号质量下降和年龄增长,以及即使没有中断操作也可能降低CI用户的语音清晰度等因素。 (NH)听众,具有全频谱和语音编码的语音(匹配的八通道和语音清晰度基线性能)。尽管实际的CI用户在理解中断的语音和利用更快的中断率和增加的占空比方面比八通道噪声频带声码监听器更加困难,但其性能却与匹配的噪声频带声码监听器相似。这些结果表明,尽管光谱时分辨率的下降确实在降低打断语音的清晰度方面起着重要作用,但仅凭这些因素并不能完全解释这一缺陷。与真实CI相关的其他因素,例如老化或基本语音提示的传输失败,似乎还导致语音中断的清晰度较差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号