Tungsten functional paper (TFP), which contains 80% tungsten by weight, has radiation‐shielding properties. We investigated the use of TFP for the protection of operators during interventional or therapeutic angiography. The air kerma rate of scattered radiation from a simulated patient was measured, with and without TFP, using a water‐equivalent phantom and fixed C‐arm fluoroscopy. Measurements were taken at the level of the operator's eye, chest, waist, and knee, with a variable number of TFP sheets used for shielding. A Monte Carlo simulation was also utilized to analyze the dose rate delivered with and without the TFP shielding. In cine mode, when the number of TFP sheets was varied through 1, 2, 3, 5, and 10, the respective reduction in the air kerma rate relative to no TFP shielding was as follows: at eye level, 24.9%, 29.9%, 41.6%, 50.4%, and 56.2%; at chest level, 25.3%, 33.1%, 34.9%, 46.1%, and 44.3%; at waist level, 45.1%, 57.0%, 64.4%, 70.7%, and 75.2%; and at knee level, 2.1%, 2.2%, 2.1%, 2.1%, and 2.1%. In fluoroscopy mode, the respective reduction in the air kerma rate relative to no TFP shielding was as follows: at eye level, 24.8%, 30.3%, 34.8%, 51.1%, and 58.5%; at chest level, 25.8%, 33.4%, 35.5%, 45.2%, and 44.4%; at waist level, 44.6%, 56.8%, 64.7%, 71.7%, and 77.2%; and at knee level, 2.2%, 0.0%, 2.2%, 2.8%, and 2.5%. The TFP paper exhibited good radiation‐shielding properties against the scattered radiation encountered in clinical settings, and was shown to have potential application in decreasing the radiation exposure to the operator during interventional radiology.
机译:钨功能纸(TFP)包含80%的钨(重量),具有辐射屏蔽性能。我们调查了在介入或治疗性血管造影过程中使用TFP来保护操作者的情况。在有或没有TFP的情况下,使用等效于水的体模和固定的C型臂荧光透视仪测量了来自模拟患者的散射辐射的空气比释动能率。在操作员的眼睛,胸部,腰部和膝盖的水平进行测量,并使用不同数量的TFP板进行屏蔽。还使用了蒙特卡罗模拟来分析带和不带TFP屏蔽时的剂量率。在电影模式下,当将TFP的张数更改为1、2、3、5和10时,相对于没有TFP屏蔽,空气比释动能降低分别为:在眼睛水平处分别为24.9%,29.9% ,41.6%,50.4%和56.2%;胸部水平分别为25.3%,33.1%,34.9%,46.1%和44.3%;腰围分别为45.1%,57.0%,64.4%,70.7%和75.2%;膝盖水平分别为2.1%,2.2%,2.1%,2.1%和2.1%。在荧光检查模式下,相对于没有TFP屏蔽,空气比释动能降低分别为:在眼水平上分别为24.8%,30.3%,34.8%,51.1%和58.5%;胸部水平分别为25.8%,33.4%,35.5%,45.2%和44.4%;腰围分别为44.6%,56.8%,64.7%,71.7%和77.2%;膝盖水平分别为2.2%,0.0%,2.2%,2.8%和2.5%。 TFP纸对临床环境中遇到的散射辐射表现出良好的辐射屏蔽性能,并且在减少介入放射学过程中对操作员的辐射暴露方面具有潜在的应用价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号