>Introduction: This in vitro study was designed to measure and compare the amount of temperature rise in the pulp chamber of the teeth exposed to different light curing units (LCU), which are being used for curing composite restorations. >Methods: The study was performed in two settings; first, an in vitro and second was mimicking an in vivo situation. In the first setup of the study, three groups were formed according to the respective three light curing sources. i.e. quartz-tungsten-halogen (QTH) unit and two light-emitting diode (LED) units (second and third generations). In the in vitro setting, direct thermal emission from three light sources at 3 mm and 6 mm distances, was measured with a k-type thermocouple, and connected to a digital thermometer. For a simulation of an in vivo situation, 30 premolar teeth were used. Class I Occlusal cavity of all the teeth were prepared and they were restored with incremental curing of composite, after bonding agent application. While curing the bonding agent and composite in layers, the intrapulpal temperature rise was simultaneously measured with a k-type thermocouple. >Results: The first setting of the study showed that the heat produced by irradiation with LCU was significantly less at 6 mm distance when compared to 3 mm distance. The second setting of the study showed that the rise of intrapulpal temperature was significantly less with third generation LED light cure units than with second generation LED and QTH light cure units. >Conclusion: As the distance from the light source increases, less irradiation heat is produced. Third generation LED lights cause the least temperature change in the pulp chamber of single rooted teeth.
机译:>简介:这项体外研究旨在测量和比较暴露于不同光固化单元(LCU)的牙齿牙髓腔中的温度升高量,这些光固化单元用于固化复合修复体。 >方法:该研究在两种环境下进行;首先,体外,其次模仿体内情况。在研究的第一个设置中,根据各自的三个光固化源形成了三组。即石英钨卤素灯(QTH)单元和两个发光二极管(LED)单元(第二代和第三代)。在体外环境中,使用k型热电偶测量了三个光源在3 mm和6 mm距离处的直接热辐射,并将其连接到数字温度计。为了模拟体内情况,使用了30颗前磨牙。准备好所有牙齿的I类咬合腔,并在应用粘合剂后通过复合材料的增量固化对其进行修复。在将粘合剂和复合材料分层固化的同时,用k型热电偶同时测量了肺内温度的升高。 >结果:该研究的第一个设置显示,与6 mm距离相比,LCU照射产生的热量明显少于3 mm距离。第二项研究表明,第三代LED光固化装置的门内温度升高明显少于第二代LED和QTH光固化装置。 >结论:随着距光源的距离增加,产生的辐射热更少。第三代LED灯在单根牙齿的牙髓腔中引起的温度变化最小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号