首页> 美国卫生研究院文献>Journal of Radiation Research >Performance evaluation of a newly developed three-dimensional model-based global-to-local registration in prostate cancer
【2h】

Performance evaluation of a newly developed three-dimensional model-based global-to-local registration in prostate cancer

机译:一种新开发的基于三维模型的前列腺癌全球至本地注册的性能评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We evaluated the performance of a newly developed three-dimensional (3D) model-based global-to-local registration of multiple organs, by comparing it with a 3D model-based global registration in the prostate region. This study included 220 prostate cancer patients who underwent intensity-modulated radiotherapy or volumetric-modulated arc therapy. Our registration proceeded sequentially, i.e. global registration including affine and piece-wise affine transformation followed by local registration. As a local registration, Laplacian-based and finite element method-based registration was implemented in Algorithm A and B, respectively. Algorithm C was for global registration alone. The template models for the prostate, seminal vesicles, rectum and bladder were constructed from the first 20 patients, and then three different registrations were performed on these organs for the remaining 200 patients, to assess registration accuracy. The 75th percentile Hausdorff distance was <1 mm in Algorithm A; it was >1 mm in Algorithm B, except for the prostate; and 3.9 mm for the prostate and >7.8 mm for other organs in Algorithm C. The median computation time to complete registration was <101, 30 and 16 s in Algorithms A, B and C, respectively. Analysis of variance revealed significant differences among Algorithms A–C in the Hausdorff distance and computation time. In addition, no significant difference was observed in the difference of Hausdorff distance between Algorithm A and B with Tukey’s multiple comparison test. The 3D model-based global-to-local registration, especially that implementing Laplacian-based registration, completed surface registration rapidly and provided sufficient registration accuracy in the prostate region.
机译:通过将其与前列腺区域中基于3D模型的全局注册进行比较,我们评估了新开发的基于三维(3D)模型的多个器官的全局到局部注册的性能。该研究包括220位接受了强度调制放射治疗或体积调制弧光治疗的前列腺癌患者。我们的注册顺序进行,即包括仿射和分段仿射变换的全局注册,然后是本地注册。作为本地注册,分别在算法A和算法B中实现了基于拉普拉斯算子和基于有限元法的注册。算法C仅用于全局注册。从前20名患者中构建前列腺,精囊,直肠和膀胱的模板模型,然后对其余200名患者在这些器官上进行三个不同的注册,以评估注册准确性。在算法A中,第75个百分点的Hausdorff距离小于1 mm;在算法B中,前列腺大于1mm;在算法C中,前列腺为3.9 mm,其他器官为> 7.8 mm。在算法A,B和C中,完成配准的中值计算时间分别为<101、30和16 s。方差分析表明,算法A–C在Hausdorff距离和计算时间上存在显着差异。此外,使用Tukey的多重比较测试,算法A和算法B之间的Hausdorff距离差异没有显着差异。基于3D模型的全局到局部配准,尤其是实现基于拉普拉斯配准的配准,可以快速完成表面配准,并在前列腺区域提供足够的配准精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号