首页> 美国卫生研究院文献>Scientific Reports >The polarization and the fundamental sensitivity of 39K (133Cs)-85Rb-4He hybrid optical pumping spin exchange relaxation free atomic magnetometers
【2h】

The polarization and the fundamental sensitivity of 39K (133Cs)-85Rb-4He hybrid optical pumping spin exchange relaxation free atomic magnetometers

机译:39K(133Cs)-85Rb-4He混合光泵浦自旋交换弛豫自由原子磁强计的偏振和基本灵敏度

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The hybrid optical pumping spin exchange relaxation free (SERF) atomic magnetometers can realize ultrahigh sensitivity measurement of magnetic field and inertia. We have studied the 85Rb polarization of two types of hybrid optical pumping SERF magnetometers based on 39K-85Rb-4He and 133Cs-85Rb-4He respectively. Then we found that 85Rb polarization varies with the number density of buffer gas 4He and quench gas N2, pumping rate of pump beam and cell temperature respectively, which will provide an experimental guide for the design of the magnetometer. We obtain a general formula on the fundamental sensitivity of the hybrid optical pumping SERF magnetometer due to shot-noise. The formula describes that the fundamental sensitivity of the magnetometer varies with the number density of buffer gas and quench gas, the pumping rate of pump beam, external magnetic field, cell effective radius, measurement volume, cell temperature and measurement time. We obtain a highest fundamental sensitivity of 1.5073 aT/Hz 1/2 (1 aT = 10−18 T) with 39K-85Rb-4He magnetometer between above two types of magnetometers when 85Rb polarization is 0.1116. We estimate the fundamental sensitivity limit of the hybrid optical pumping SERF magnetometer to be superior to 1.8359 × 10−2 aT/Hz 1/2, which is higher than the shot-noise-limited sensitivity of 1 aT/Hz 1/2 of K SERF atomic magnetometer.
机译:混合光学泵浦无自旋交换弛豫(SERF)原子磁力计可以实现磁场和惯性的超高灵敏度测量。我们研究了基于 39 K- 85 Rb- 4 <的两种类型的混合光泵浦SERF磁力计的 85 Rb极化/ sup> He和 133 Cs- 85 Rb- 4 He。然后我们发现 85 Rb极化随缓冲气体 4 He和淬灭气体N2的数量密度,泵浦束的泵浦速率和电池温度而变化,这将提供一个磁力计设计的实验指南。我们获得了由散粒噪声引起的混合光泵浦SERF磁力计基本灵敏度的一般公式。该公式描述了磁力计的基本灵敏度随缓冲气体和淬灭气体的数量密度,泵浦光束的抽速,外部磁场,电池有效半径,测量体积,电池温度和测量时间而变化。我们获得最高基本灵敏度1.5073 aT / Hz 1/2 (1 aT = 10 −18 T)和 39 K- 85 Rb极化度为0.1116时,上述两种磁力计之间的> 85 Rb- 4 He磁力仪。我们估计混合光泵浦SERF磁力计的基本灵敏度极限要优于1.8359×10 −2 aT / Hz 1/2 K SERF原子磁力计的噪声限制灵敏度为1 aT / Hz 1/2

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号