首页> 美国卫生研究院文献>Scientific Reports >Fixation Characteristics in Highly Myopic Eyes: the Shanghai High Myopia Study
【2h】

Fixation Characteristics in Highly Myopic Eyes: the Shanghai High Myopia Study

机译:高度近视眼的固定特性:上海高度近视研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We enrolled 500 highly myopic eyes and 50 controls in this hospital-based prospective cohort study. The fixation ellipse angle and area in terms of the bivariate contour ellipse area (BCEA) were measured with Macular Integrity Assessment microperimetry. Optic disc tilt and rotation were evaluated with retinal images. The associations between fixation and optic disc changes were assessed. Both 63% and 95% BCEA correlated positively with axial length (AL) (both r = 0.230, P = 0.001) in highly myopic group, and were significantly higher than the control group (both P < 0.001). The direction of fixation ellipse presented clockwise rotation in the right eyes and anti-clockwise rotation in the left eyes with the increase of AL in highly myopic group (AL ≥30 vs <30 mm: OD 76.12 ± 51.17°: vs 90.60° ± 51.28°, P = 0.029; OS 94.73 ± 57.45° vs 87.82 ± 55.15°, P = 0.371). The angle between the long axis of the fixation ellipse and the long axis of the optic disc (AngleF−D) distributed in various directions: 0–30° (34.6% almost parallel) ≈60–90° (34.4% almost vertical) >30–60° (31% oblique). AngleF−D increased slightly with the AL (r = 0.105, P = 0.024). In highly myopic eyes, fixation stability decreased with the AL, and superior rotation of the fixation ellipse increased with AL. The long axis of fixation ellipse and the long axis of optic disc became less parallel to each other with increasing AL. Our data may provide clues for improvement of fixation evaluation designs of biometric instruments.
机译:在这项基于医院的前瞻性队列研究中,我们纳入了500只高度近视眼和50位对照。用黄斑完整性评估微视野术测量以二元轮廓椭圆面积(BCEA)表示的固定椭圆角和面积。用视网膜图像评估视盘的倾斜和旋转。评估固定与视盘改变之间的关联。在高度近视组中,BCEA的63%和95%都与轴长(AL)呈正相关(r = 0.230,P = 0.001),并且显着高于对照组(P <0.001)。在高度近视组中,固定椭圆的方向呈现右眼顺时针旋转和左眼逆时针旋转(AL≥30 vs <30 mm:OD 76.12±51.17°:vs 90.60°±51.28) °,P = 0.029; OS 94.73±57.45°与87.82±55.15°,P = 0.371)。固定椭圆的长轴与视盘的长轴(AngleF-D)之间的角度分布于各个方向:0–30°(几乎平行的34.6%)≈60–90°(几乎垂直的34.4%)> 30–60°(31%倾斜)。角度F-D随AL而略微增加(r = 0.105,P,= 0.024)。在高度近视的眼睛中,固定稳定性随AL降低,而固定椭圆的出色旋转随AL增加。随着AL的增加,固定椭圆的长轴和视盘的长轴变得不太平行。我们的数据可能为改进生物识别仪器的固定评估设计提供线索。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号