首页> 美国卫生研究院文献>Scientific Reports >Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery
【2h】

Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery

机译:扫频光学相干断层扫描生物仪作为计划白内障手术患者黄斑疾病的筛查策略

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled for cataract surgery. 1,114 eyes of 749 consecutive patients underwent a biometrical examination with IOLMaster 700 SS-OCT technology (Carl Zeiss) and conventional Spectral-Domain OCT (SD-OCT) (Spectralis OCT, Heidelberg) device analysis on the same day. Seven examiners graded the scans individually in a full-masked mode. Twenty-five eyes were excluded for media opacities. Among the 1,089 included eyes, statistical analysis revealed a mean Kendall’s Coefficient of 0.83 (range 0.76–0.89). A logistic regression model demonstrated a highly significant correlation (p < 0.001) between the coefficient of concordance and SD-OCT imaging. Intraobserver reproducibility was 0.89 (range 0.86–0.91). Optical biometer SS-OCT scans showed a mean sensitivity of 0.81 and a mean specificity of 0.84. The positive and negative predictive value detected was 0.78 and 0.86, respectively. In order to predict the risk of reduced visual recovery, especially in cases of retinal pathology, optical biometer with SS-OCT scan has proven to be a useful modality for detecting macular structural abnormalities in patients undergoing cataract surgery. Conventional SD-OCT remains mandatory to confirm the presumed diagnosis.
机译:这项研究的目的是评估基于全眼长扫频OCT(SS-OCT)扫描的光学生物计捕获的中央黄斑成像,以此作为筛查计划白内障患者黄斑疾病的筛查策略。同一天,对749例连续患者的1,114眼进行了生物特征检查,方法是使用IOLMaster 700 SS-OCT技术(卡尔·蔡司)和常规的光谱域OCT(SD-OCT)(Spectralis OCT,海德堡)进行设备分析。七名检查员以全遮蔽模式分别对扫描进行评分。排除了25只眼的媒体混浊。在1089只眼睛中,统计分析显示肯德尔的平均系数为0.83(范围为0.76-0.89)。 Logistic回归模型表明一致性系数与SD-OCT成像之间存在高度显着的相关性(p <0.001)。观察者内可重复性为0.89(范围为0.86-0.91)。光学生物计SS-OCT扫描显示平均灵敏度为0.81,平均特异性为0.84。检测到的阳性和阴性预测值分别为0.78和0.86。为了预测视力恢复降低的风险,特别是在视网膜病变的情况下,带有SS-OCT扫描功能的光学生物计已被证明是检测白内障手术患者黄斑结构异常的有用方式。常规SD-OCT仍然是强制性的,以确认假定的诊断。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号