Needle-based storage-phosphor detector radiography is superior to a conventional powder-based storage phosphor detector and a high-resolution screen-film system in small patients (budgerigars and mice)

机译:在小患者(虎皮鹦鹉和老鼠)中基于针的存储磷检测器射线照相优于传统的基于粉末的存储磷检测器和高分辨率屏幕胶片系统

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This method comparison study used radiographs of 20 mice and 20 budgerigars to investigate comparability between computed radiography (CR) and high-resolution screen-film systems and study the effects of reduced radiation doses on image quality of digital radiographs of small patients. Exposure settings used with the mammography screen-film system (SF) were taken as baseline settings. A powder-based storage-phosphor system (CRP) and a needle-based storage-phosphor system (CRN) were used with the same settings (D/100%) and half the detector dose (D/50%). Using a scoring system four reviewers assessed five criteria per species covering soft tissue and bone structures. Results were evaluated for differences between reviewers (interobserver variability), systems and settings (intersystem variability, using visual grading characteristic analysis). Correlations were significant (p ≤ 0.05) for interobserver variability in 86.7% of the cases. Correlation coefficients ranged from 0.206 to 0.772. For mice and budgerigars, the CRN system was rated as superior to the SF and CRP system for most criteria, being significant in two cases each. Comparing the SF and CRP system, the conventional method scored higher for all criteria, in one case significantly. For both species and both digital systems, dose reduction to 50% resulted in significantly worse scores for most criteria. In summary, the needle-based storage-phosphor technique proved to be superior compared to the conventional storage-phosphor and mammography screen-film system. Needle-based detector systems are suitable substitutes for high-resolution screen–film systems when performing diagnostic imaging of small patients. Dose reduction to 50% of the corresponding dose needed in high-resolution film-screen systems cannot be recommended.
机译:这项方法比较研究使用了20只小鼠和20个虎皮鹦鹉的X射线照片来研究计算机X射线照片(CR)与高分辨率屏幕胶片系统之间的可比性,并研究减少辐射剂量对小患者数字X射线照片的图像质量的影响。与乳腺X光摄影胶片系统(SF)一起使用的曝光设置被用作基线设置。使用基于粉末的储磷系统(CRP)和基于针的储磷系统(CRN),设置相同(D / 100%),检测器剂量减半(D / 50%)。使用评分系统,四位审稿人评估了每种物种涵盖软组织和骨骼结构的五个标准。评估结果以评估审阅者(观察者间的变异性),系统和设置(系统间的变异性,使用视觉分级特征分析)之间的差异。在86.7%的病例中,观察者间差异具有显着性(p≤0.05)。相关系数范围从0.206到0.772。对于小鼠和虎皮鹦鹉,在大多数标准下,CRN系统被评为优于SF和CRP系统,在两种情况下均显着。比较SF和CRP系统,在所有情况下,传统方法的得分都较高,其中一种情况显着。对于物种和两个数字系统而言,将剂量减少到50%会使大多数标准的得分大大降低。总之,与常规的存储荧光粉和乳房X线照相屏幕胶片系统相比,基于针的存储荧光粉技术被证明是优越的。当对小患者进行诊断成像时,基于针的检测器系统是高分辨率屏幕胶片系统的合适替代品。不建议将剂量减少到高分辨率胶片屏幕系统所需的相应剂量的50%。

著录项