Reliability Validity and Minimal Detectable Change of Four-Step Stair ClimbPower Test in Community-Dwelling Older Adults

机译:四步楼梯爬升的可靠性有效性和最小可检测变化社区居住的老年人的力量测试

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background. Stair climb power is an important clinical measure of lower-extremity power. The stair climb power test (SCPT) was validated by requiring individuals to climb a full flight of stairs. A 4-step SCPT (4SCPT) would be more clinically feasible and easier to perform, yet its reliability and validity are unknown. >Objective. To evaluate reliability, validity, and minimal detectable change of 4SCPT among community-dwelling older adults. >Design. This study is a cross-sectional analysis of baseline data from a clinical trial. >Methods. Fifty older adults ≥65 years of age, at risk for mobility decline, consented to participate in this ancillary study. Test-retest reliability was derived from 2 measurements within each participant measured by a single assessor. Pearson correlation analyses among leg power measures (4SCPT, SCPT, single leg press power at 40% and 70% of the 1-repetition maximum [SLP40, SLP70]) were performed. Separate multivariate linear regressions were conducted evaluating the associations between each leg power measure and 2 mobility outcomes, the Short Physical Performance Battery (SPPB) and habitual gait speed(HGS). Minimal detectable change was based on a 90% confidence interval(MDC90).>Results. The 4SCPT had excellent test-retest reliability (ICC(2,1) = 0.951),and strong correlation with SCPT, SLP40, and SLP70 (r = 0.85-0.96). The4SCPT explained a greater amount of variance in the SPPB (R2 = 0.31) than otherleg power measurements (R2 = 0.23-0.25). The 4SCPT (R2 = 0.41) andSCPT (R2 = 0.42) described equivalent amounts of variance in HGS, and greaterthan that with SLP40 (R2 = 0.28) and SLP70 (R2 = 0.30). TheMDC90 for 4SCPT was 44.0 watts.>Limitations. This was a cross-sectional analysis within a small,nonrepresentative sample. Interrater reliability was not evaluated.>Conclusions. The 4SCPT shows scientific promise as a valid and reliable legpower measurement among community-dwelling older adults.
机译:>背景。爬楼梯的力量是降低下肢力量的重要临床指标。楼梯爬升力测试(SCPT)通过要求个人爬完整的楼梯来验证。 4步SCPT(4SCPT)在临床上更可行,更易于执行,但其可靠性和有效性尚不清楚。 >目标。评估社区居住的老年人中4SCPT的可靠性,有效性和最小的可检测变化。 >设计。这项研究是对一项临床试验的基线数据进行的横断面分析。 >方法。五十名年龄≥65岁,有活动能力下降风险的成年人同意参加这项辅助研究。重测信度是由单个评估者在每个参与者内部进行的2次测量得出的。进行了腿部力量测量(4SCPT,SCPT,单腿按压力量为1次重复最大值的40%和70%[SLP40,SLP70])之间的Pearson相关分析。进行了单独的多元线性回归,评估了每个腿部力量测量与2个活动性结局,短物理表现电池(SPPB)和习惯步态速度之间的关联(HGS)。最小的可检测变化基于90%的置信区间(MDC90)。>结果。4SCPT具有出色的重测可靠性(ICC(2,1)= 0.951),与SCPT,SLP40和SLP70密切相关(r = 0.85-0.96)。的4SCPT解释了SPPB中的差异较大(R 2 = 0.31)腿部力量测量值(R 2 = 0.23-0.25)。 4SCPT(R 2 = 0.41)和SCPT(R 2 = 0.42)描述了HGS中等价的变化量,并且更大与SLP40(R 2 = 0.28)和SLP70(R 2 = 0.30)相比。的4SCPT的MDC90为44.0瓦。>限制。这是在很小的范围内进行的横截面分析,非代表性样本。评估者间信度未评估。>结论。4SCPT显示出科学的承诺,是有效而可靠的一环社区居民中老年人的功率测量。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号