首页> 美国卫生研究院文献>Journal of Endovascular Therapy >Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair
【2h】

Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

机译:血管内动脉瘤修复后水蟒支架移植物近端密封环的演变

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). >Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort study (LSPEAS; Trialregister.nl identifier NTR4276). The patients were treated electively using an Anaconda stent-graft with a mean 31% oversizing (range 17–47). According to protocol, participants were to be followed for 2 years, during which 5 noncontrast electrocardiogram-gated computed tomography scans would be conducted. Three patients were eliminated within 30 days (1 withdrew, 1 died, and a third was converted before stent-graft deployment), leaving 15 patients (mean age 72.8±3.7 years; 14 men) for this analysis. Evolution in size and shape (symmetry) of both proximal infrarenal sealing rings were assessed from discharge to 24 months using dedicated postprocessing algorithms. >Results: At 24 months, the mean diameters of the first and second ring stents had increased significantly (first ring: 2.2±1.0 mm, p<0.001; second ring: 2.7±1.1 mm, p<0.001). At 6 months, the first and second rings had expanded to a mean 96.6%±2.1% and 94.8%±2.7%, respectively, of their nominal diameter, after which the rings expanded slowly; ring diameters stabilized to near nominal size (first ring, 98.3%±1.1%; second ring, 97.2%±1.4%) at 24 months irrespective of initial oversizing. No type I or III endoleaks or aneurysm-, device-, or procedure-related adverse events were noted in follow-up. The difference in the diametric distances between the peaks and valleys of the saddle-shaped rings was marked at discharge but became smaller after 24 months for both rings (first ring: median 2.0 vs 1.2 mm, p=0.191; second ring: median 2.8 vs 0.8 mm; p=0.013). >Conclusion: Irrespective of initial oversizing, the Anaconda proximal sealing rings radially expanded to near nominal size within 6 months after EVAR. Initial oval-shaped rings conformed symmetrically and became nearly circular through 24 months. These findings should be taken into account in planning and follow-up.
机译:>目的:目的是深入了解血管内动脉瘤修复(EVAR)后Anaconda支架移植物的鞍形近端密封环的演变过程。 >方法:连续纳入了18例腹主动脉瘤患者,进行单中心,前瞻性,观察性队列研究(LSPEAS; Trialregister.nl标识符NTR4276)。使用Anaconda支架移植物对患者进行选择性治疗,平均移植物过大31%(范围17-47)。根据协议,参与者将被随访2年,在此期间将进行5次非对比心电门控计算机断层扫描。在30天内淘汰了3例患者(1例退出,1例死亡,第3例在支架植入之前被转换),剩下15例患者(平均年龄72.8±3.7岁; 14例男性)用于此分析。使用专门的后处理算法,评估了从出院到24个月,两个近端肾下密封环的大小和形状(对称性)的演变。 >结果:在第24个月时,第一环和第二环支架的平均直径显着增加(第一环:2.2±1.0 mm,p <0.001;第二环:2.7±1.1 mm,p <0.001 )。在第6个月时,第一个和第二个环分别膨胀至其标称直径的平均96.6%±2.1%和94.8%±2.7%,此后,这些环缓慢扩张;不管最初的尺寸是否过大,在24个月时,环直径均稳定在接近标称尺寸(第一环为98.3%±1.1%;第二环为97.2%±1.4%)。随访中未发现I型或III型内漏或与动脉瘤,装置或手术相关的不良事件。鞍形环的峰和谷之间的直径距离差异在放电时明显,但两个环在24个月后变小(第一环:中位数2.0对1.2毫米,p = 0.191;第二环:中位数2.8对vs 0.8毫米; p = 0.013)。 >结论:无论最初的尺寸是多少,Anaconda近端密封环在EVAR后6个月内都会径向扩张至接近标称尺寸。最初的椭圆形环对称对称,并在24个月内几乎变为圆形。在计划和后续行动中应考虑这些发现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号