首页> 美国卫生研究院文献>Journal of Applied Physiology >Discharge properties of motor units during steady isometric contractions performed with the dorsiflexor muscles
【2h】

Discharge properties of motor units during steady isometric contractions performed with the dorsiflexor muscles

机译:用背屈肌进行稳定等距收缩时运动单位的放电特性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this study was to record the discharge characteristics of tibialis anterior motor units over a range of target forces and to import these data, along with previously reported observations, into a computational model to compare experimental and simulated measures of torque variability during isometric contractions with the dorsiflexor muscles. The discharge characteristics of 44 motor units were quantified during brief isometric contractions at torques that ranged from recruitment threshold to an average of 22 ± 14.4% maximal voluntary contraction (MVC) torque above recruitment threshold. The minimal [range: 5.8–19.8 pulses per second (pps)] and peak (range: 8.6–37.5 pps) discharge rates of motor units were positively related to the recruitment threshold torque (R2 ≥ 0.266; P < 0.001). The coefficient of variation for interspike interval at recruitment was positively associated with recruitment threshold torque (R2 = 0.443; P < 0.001) and either decreased exponentially or remained constant as target torque increased above recruitment threshold torque. The variability in the simulated torque did not differ from the experimental values once the recruitment range was set to ∼85% MVC torque, and the association between motor twitch contraction times and peak twitch torque was defined as a weak linear association (R2 = 0.096; P < 0.001). These results indicate that the steadiness of isometric contractions performed with the dorsiflexor muscle depended more on the distributions of mechanical properties than discharge properties across the population of motor units in the tibialis anterior.
机译:这项研究的目的是记录胫骨前运动单元在一系列目标作用力下的放电特性,并将这些数据以及先前报告的观察结果导入到一个计算模型中,以比较等轴测收缩期间扭矩变化的实验和模拟测量与背屈肌。在短暂的等距收缩期间,以从补充阈值到平均高于补充阈值的最大最大自愿收缩(MVC)扭矩的平均值为22±14.4%的扭矩,对44个电机单元的放电特性进行了量化。电机单元的最小[范围:5.8–19.8脉冲/秒(pps)]和峰值(范围:8.6–37.5 pps)的放电速率与恢复阈值扭矩(R 2 ≥0.266)正相关; P <0.001)。募集期间刺突间期的变异系数与募集阈值转矩正相关(R 2 = 0.443; P <0.001),并且随着目标转矩增加到募集阈值转矩以上而呈指数下降或保持恒定。将补充范围设定为〜85%MVC扭矩后,模拟扭矩的变化与实验值没有差异,并且将电机抽动收缩时间与峰值抽动扭矩之间的关联定义为弱线性关联(R 2 = 0.096; P <0.001)。这些结果表明,用背屈肌进行等轴测收缩的稳定性更多地取决于机械性能的分布,而不是整个胫骨前肌运动单元的放电性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号