首页> 美国卫生研究院文献>American Journal of Physiology - Gastrointestinal and Liver Physiology >Flow time through esophagogastric junction derived during high-resolution impedance-manometry studies: a novel parameter for assessing esophageal bolus transit
【2h】

Flow time through esophagogastric junction derived during high-resolution impedance-manometry studies: a novel parameter for assessing esophageal bolus transit

机译:高分辨率阻抗测压研究中通过食管胃交界处的流动时间:评估食管推注转运的新参数

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This study aimed to develop and validate a method to measure bolus flow time (BFT) through the esophagogastric junction (EGJ) using a high-resolution impedance-manometry (HRIM) sleeve. Ten healthy subjects were studied with concurrent HRIM and videofluoroscopy; another 15 controls were studied with HRIM alone. HRIM studies were performed using a 4.2-mm-outer diameter assembly with 36 pressure sensors at 1-cm intervals and 18 impedance segments at 2-cm intervals (Given Imaging, Los Angeles, CA). HRIM and fluoroscopic data from four barium swallows, two in the supine and two in the upright position, were analyzed to create a customized MATLAB program to calculate BFT using a HRIM sleeve comprising three sensors positioned at the crural diaphragm. Bolus transit through the EGJ measured during blinded review of fluoroscopy was almost identical to BFT calculated with the HRIM sleeve, with the nadir impedance deflection point used as the signature of bolus presence. Good correlation existed between videofluoroscopy for measurement of upper sphincter relaxation to beginning of flow [R = 0.97, P < 0.001 (supine) and R = 0.77, P < 0.01 (upright)] and time to end of flow [R = 0.95, P < 0.001 (supine) and R = 0.82, P < 0.01 (upright)]. The medians and interquartile ranges (IQR) of flow time though the EGJ in 15 healthy subjects calculated using the virtual sleeve were 3.5 s (IQR 2.3–3.9 s) in the supine position and 3.2 s (IQR 2.3–3.6 s) in the upright position. BFT is a new metric that provides important information about bolus transit through the EGJ. An assessment of BFT will determine when the EGJ is open and will also provide a useful method to accurately assess trans-EGJ pressure gradients during flow.
机译:这项研究旨在开发和验证一种使用高分辨率阻抗测压(HRIM)套管测量通过食管胃交界处(EGJ)的推注流动时间(BFT)的方法。十名健康受试者同时进行了HRIM和荧光透视检查。仅使用HRIM研究了另外15个对照。 HRIM研究是使用外径为4.2 mm的组件进行的,该组件具有36个压力传感器(间隔为1厘米)和18个阻抗段(间隔为2厘米)(Given Imaging,洛杉矶,加利福尼亚州)。分析了来自四个钡剂燕子(两个处于仰卧状态,两个处于直立位置)的HRIM和荧光检查数据,以创建定制的MATLAB程序,以使用HRIM套筒(包括位于横隔膜处的三个传感器)来计算BFT。通过透视检查在盲法检查中测得的小球通过EGJ的过程与使用HRIM套筒计算的BFT几乎相同,最低点阻抗偏转点用作大剂量存在的标志。在测量上括约肌松弛到血流开始的视频荧光检查[R = 0.97,P <0.001(仰卧)和R = 0.77,P <0.01(直立)]与血流终止时间之间存在良好的相关性[R = 0.95,P <0.001(仰卧),R = 0.82,P <0.01(直立)]。使用虚拟袖套计算出的15名健康受试者通过EGJ的流动时间的中位数和四分位间距(IQR)在仰卧位为3.5 s(IQR 2.3-3.9 s),在直立位置为3.2 s(IQR 2.3-3.6 s)位置。 BFT是一项新指标,可提供有关通过EGJ推注转运的重要信息。对BFT的评估将确定EGJ何时打开,还将提供一种有用的方法来准确评估流动过程中的跨EGJ压力梯度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号