首页> 美国卫生研究院文献>Journal of Analytical Toxicology >Quantification of Polybrominated and Polychlorinated Biphenyls in Human Matrices by Isotope-Dilution Gas Chromatography–Tandem Mass Spectrometry
【2h】

Quantification of Polybrominated and Polychlorinated Biphenyls in Human Matrices by Isotope-Dilution Gas Chromatography–Tandem Mass Spectrometry

机译:同位素稀释气相色谱-串联质谱法定量测定人体基质中的多溴联苯和多氯联苯

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We have developed a highly sensitive and selective analytical method capable of quantifying a total of 15 polybrominated and polychlorinated biphenyls (11 PBBs and 4 PCBs) in human serum. Samples were subjected to liquid–liquid extraction followed by solid-phase extraction prior to measurement using gas chromatography–tandem mass spectrometry in multiple reaction monitoring mode. Quantification was performed using isotope-dilution calibration covering a concentration range of 0.005–12.5 ng/mL. Limits of detection for all target compounds were in the low range (0.7–6.5 pg/mL). The method was validated using in-house pooled human serum fortified at two concentrations (0.5 ng/mL and 1.0 ng/mL), whole semen fortified at one concentration (0.25 ng/mL), and NIST Standard Reference Material (SRM) 1958, which includes five of the target compounds. Method accuracies for all target compounds ranged from 84 to 119% with relative standard deviations (RSDs) of <19%. The measured values for the five target compounds present in the SRM agreed with the certified reference values (89–119% accuracy with RSDs <9%). As this method was developed to support ongoing epidemiologic investigations, we evaluated its suitability by analyzing subsets of serum and whole semen samples from the Michigan PBB Registry cohort. PBB-153, PCB-118, PCB-138, PCB-153 and PCB-180 were detected in all serum samples analyzed, with PBB-77 and PBB-101 detected less frequently in serum. PBB-153, PCB-118, PCB-138, PCB-153 and PCB-180 were detected in at least one whole semen sample.
机译:我们已经开发出一种高度灵敏的选择性分析方法,能够定量测定人血清中的15种多溴联苯和多氯联苯(11种PBB和4种PCB)。样品先进行液-液萃取,然后进行固相萃取,然后使用气相色谱-串联质谱法在多反应监测模式下进行测量。使用同位素稀释校准法进行定量,浓度范围为0.005–12.5 ng / mL。所有目标化合物的检出限均在低范围内(0.7–6.5 pg / mL)。使用两种浓度(0.5 ng / mL和1.0 ng / mL)强化的内部混合人血清,一种浓度(0.25 ng / mL)强化的全精液和1958年的NIST标准参考材料(SRM)对该方法进行了验证其中包括五个目标化合物。所有目标化合物的方法准确度在84%至119%之间,相对标准偏差(RSD)<19%。 SRM中存在的五个目标化合物的测量值与认证的参考值一致(RSD <9%的准确度为89–119%)。由于开发了该方法以支持正在进行的流行病学调查,因此我们通过分析来自密歇根州PBB注册机构队列的血清和整个精液样本的子集来评估其适用性。在所有分析的血清样品中均检测到PBB-153,PCB-118,PCB-138,PCB-153和PCB-180,而在血清中检出PBB-77和PBB-101的频率较低。在至少一个完整的精液样本中检测到PBB-153,PCB-118,PCB-138,PCB-153和PCB-180。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号