首页> 美国卫生研究院文献>International Journal of Oncology >Radiofrequency radiation at Stockholm Central Railway Station in Sweden and some medical aspects on public exposure to RF fields
【2h】

Radiofrequency radiation at Stockholm Central Railway Station in Sweden and some medical aspects on public exposure to RF fields

机译:瑞典斯德哥尔摩中央火车站的射频辐射以及公众暴露在射频场中的某些医学问题

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The Stockholm Central Railway Station in Sweden was investigated for public radiofrequency (RF) radiation exposure. The exposimeter EME Spy 200 was used to collect the RF exposure data across the railway station. The exposimeter covers 20 different radiofrequency bands from 88 to 5,850 MHz. In total 1,669 data points were recorded. The median value for total exposure was 921 μW/m2 (or 0.092 μW/cm2; 1 μW/m2=0.0001 μW/cm2) with some outliers over 95,544 μW/m2 (6 V/m, upper detection limit). The mean total RF radiation level varied between 2,817 to 4,891 μW/m2 for each walking round. High mean measurements were obtained for GSM + UMTS 900 downlink varying between 1,165 and 2,075 μW/m2. High levels were also obtained for UMTS 2100 downlink; 442 to 1,632 μW/m2. Also LTE 800 downlink, GSM 1800 downlink, and LTE 2600 downlink were in the higher range of measurements. Hot spots were identified, for example close to a wall mounted base station yielding over 95,544 μW/m2 and thus exceeding the exposimeter's detection limit. Almost all of the total measured levels were above the precautionary target level of 3–6 μW/m2 as proposed by the BioInitiative Working Group in 2012. That target level was one-tenth of the scientific benchmark providing a safety margin either for children, or chronic exposure conditions. We compare the levels of RF radiation exposures identified in the present study to published scientific results reporting adverse biological effects and health harm at levels equivalent to, or below those measured in this Stockholm Central Railway Station project. It should be noted that these RF radiation levels give transient exposure, since people are generally passing through the areas tested, except for subsets of people who are there for hours each day of work.
机译:对瑞典斯德哥尔摩中央火车站的公共射频(RF)辐射进行了调查。辐射仪EME Spy 200用于收集火车站的RF暴露数据。测光仪覆盖从88到5,850 MHz的20个不同的无线电频带。总共记录了1,669个数据点。总曝光量的中位数为921μW/ m 2 (或0.092μW/ cm 2 ; 1μW/ m 2 = 0.0001μW/ cm 2 ),有些离群值超过95,544μW/ m 2 (6 V / m,检测上限)。每个步行回合的平均总RF辐射水平在2,817至4,891μW/ m 2 之间变化。 GSM + UMTS 900下行链路的平均测量值高,介于1,165和2,075μW/ m 2 之间。 UMTS 2100下行链路也获得了很高的级别; 442至1,632μW/ m 2 。 LTE 800下行链路,GSM 1800下行链路和LTE 2600下行链路也在更高的测量范围内。确定了热点,例如靠近壁挂式基站的热点,产生的热点超过95544μW/ m 2 ,从而超过了测光计的检测极限。几乎所有测得的总水平都高于BioInitiative工作组在2012年提出的3-6 µW / m 2 预防目标水平。该目标水平是提供科学基准的十分之一儿童或长期接触条件下的安全裕度。我们将本研究中确定的RF辐射暴露水平与已发表的报告有害生物效应和健康危害的科学结果进行了比较,该水平等于或低于该斯德哥尔摩中央火车站项目中测得的水平。应当指出,这些RF辐射水平会造成短暂的暴露,因为人们通常会经过测试区域,除了每天工作时间都在那儿的人的一部分。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号