首页> 美国卫生研究院文献>Experimental and Therapeutic Medicine >Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction
【2h】

Feasibility and efficacy of a remote real-time wireless ECG monitoring and stimulation system for management of ventricular arrhythmia in rabbits with myocardial infarction

机译:远程实时无线心电图监测和刺激系统治疗心肌梗死兔室性心律失常的可行性和有效性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this study was to explore the feasibility of continuous remote monitoring, and the induction and termination of malignant ventricular arrhythmias (VAs) by a novel implantable electronic cardiovascular device (IECD) system in rabbits with myocardial infarction (MI). The IECD was implanted and MI was induced by ligation of the left anterior descending coronary artery in 20 adult rabbits. Internet-based remote electrocardiogram (ECG) monitoring and ventricular stimulation were conducted in remote locations with internet access. The voltage amplitudes of the stimulation signals were recorded synchronously by remote and surface ECG. Programmed stimulation with regular stimuli and regular stimuli with an added extra stimulus were performed prior to and following the MI surgery to induce and terminate VAs. IECD implantation and MI surgery, as well as qualified remote and bidirectional signal communications between the implanted IECD and extracorporeal system, were successfully achieved in 18 rabbits. The voltage of the stimulation signals recorded by the remote and surface ECGs showed a good correlation with the stimulation current (remote ECG, r=0.972 and surface ECG, r=0.988; P<0.001). Sustained ventricular tachycardia (VT) was induced in five rabbits (5/20, 25%) prior to MI induction and in 12 rabbits (12/16, 75%) following MI induction. Of the 17 induced VTs, 16 were successfully terminated by remote ventricular stimulation. The novel IECD system provides qualified remote wireless ECG monitoring and possesses the potential to induce and terminate VAs by remote ventricular pacing in this rabbit model of MI. Thus, this model of MI may be used to test the efficacy of novel drugs and devices for the management of VAs.
机译:这项研究的目的是探讨一种新型的植入式电子心血管设备(IECD)系统在患有心肌梗死(MI)的兔子中进行连续远程监测以及诱导和终止恶性室性心律失常(VAs)的可行性。通过结扎20只成年兔的冠状动脉左前降支,植入IECD并诱导MI。在可访问互联网的偏远地区进行了基于Internet的远程心电图(ECG)监测和心室刺激。远程和表面心电图同步记录刺激信号的电压幅度。在MI手术之前和之后进行有规则刺激的程序性刺激和有额外刺激的规则刺激,以诱发和终止VA。在18只兔子中成功完成了IECD植入和MI手术,以及在植入的IECD和体外系统之间进行了合格的远程和双向信号通信。远端心电图和表面心电图记录的刺激信号电压显示出与刺激电流的良好相关性(远程ECG,r = 0.972和表面ECG,r = 0.988; P <0.001)。诱发心肌梗死前5只兔子(5 / 20,25%)和诱发心肌梗死后12只兔子(12/16,75%)诱发持续性室性心动过速(VT)。在17个诱发的VT中,有16个通过远程心室刺激成功终止。新颖的IECD系统可提供合格的远程无线ECG监测,并具有在这种MI兔模型中通过远程心室起搏诱导和终止VA的潜力。因此,该MI模型可用于测试新型药物和用于VAs管理的装置的功效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号