首页> 美国卫生研究院文献>American Journal of Physiology - Heart and Circulatory Physiology >Parameter sensitivity analysis of a lumped-parameter model of a chain of lymphangions in series
【2h】

Parameter sensitivity analysis of a lumped-parameter model of a chain of lymphangions in series

机译:串联的一系列淋巴结集总参数模型的参数敏感性分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Any disruption of the lymphatic system due to trauma or injury can lead to edema. There is no effective cure for lymphedema, partly because predictive knowledge of lymphatic system reactions to interventions is lacking. A well-developed model of the system could greatly improve our understanding of its function. Lymphangions, defined as the vessel segment between two valves, are the individual pumping units. Based on our previous lumped-parameter model of a chain of lymphangions, this study aimed to identify the parameters that affect the system output the most using a sensitivity analysis. The system was highly sensitive to minimum valve resistance, such that variations in this parameter caused an order-of-magnitude change in time-average flow rate for certain values of imposed pressure difference. Average flow rate doubled when contraction frequency was increased within its physiological range. Optimum lymphangion length was found to be some 13–14.5 diameters. A peak of time-average flow rate occurred when transmural pressure was such that the pressure-diameter loop for active contractions was centered near maximum passive vessel compliance. Increasing the number of lymphangions in the chain improved the pumping in the presence of larger adverse pressure differences. For a given pressure difference, the optimal number of lymphangions increased with the total vessel length. These results indicate that further experiments to estimate valve resistance more accurately are necessary. The existence of an optimal value of transmural pressure may provide additional guidelines for increasing pumping in areas affected by edema.
机译:由于创伤或伤害造成的淋巴系统的任何破坏都可能导致水肿。目前尚无有效的淋巴水肿治疗方法,部分原因是缺乏对干预措施的淋巴系统反应的预测知识。一个完善的系统模型可以极大地增进我们对其功能的理解。淋巴结被定义为两个泵之间的血管段。基于我们先前的淋巴结链的集总参数模型,本研究旨在通过敏感性分析来确定对系统输出影响最大的参数。该系统对最小的阀门阻力高度敏感,因此对于某些施加的压力差值,此参数的变化会导致时间平均流量发生数量级变化。当收缩频率在其生理范围内增加时,平均流速增加一倍。发现最佳的淋巴结长度约为13-14.5直径。当透壁压力使主动收缩的压力直径环位于最大被动血管顺应性附近时,会出现时间平均流量的峰值。在存在较大不利压力差的情况下,增加链中淋巴结的数量可改善泵送效果。对于给定的压差,最佳的淋巴结数目随总血管长度的增加而增加。这些结果表明,需要进行进一步的实验以更准确地估算阀门阻力。透壁压力的最佳值的存在可为在受水肿影响的区域增加泵送提供其他指导。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号