首页> 美国卫生研究院文献>American Journal of Epidemiology >Evaluation of the 24-Hour Recall as a Reference Instrument for CalibratingOther Self-Report Instruments in Nutritional Cohort Studies: Evidence From the ValidationStudies Pooling Project
【2h】

Evaluation of the 24-Hour Recall as a Reference Instrument for CalibratingOther Self-Report Instruments in Nutritional Cohort Studies: Evidence From the ValidationStudies Pooling Project

机译:将24小时召回作为校准的参考仪器进行评估营养队列研究中的其他自我报告工具:来自验证的证据研究汇集项目

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Calibrating dietary self-report instruments is recommended as a way to adjust for measurement error when estimating diet-disease associations. Because biomarkers available for calibration are limited, most investigators use self-reports (e.g., 24-hour recalls (24HRs)) as the reference instrument. We evaluated the performance of 24HRs as reference instruments for calibrating food frequency questionnaires (FFQs), using data from the Validation Studies Pooling Project, comprising 5 large validation studies using recovery biomarkers. Using 24HRs as reference instruments, we estimated attenuation factors, correlations with truth, and calibration equations for FFQ-reported intakes of energy and for protein, potassium, and sodium and their densities, and we compared them with values derived using biomarkers. Based on 24HRs, FFQ attenuation factors were substantially overestimated for energy and sodium intakes, less for protein and potassium, and minimally for nutrient densities. FFQ correlations with truth, based on 24HRs, were substantially overestimated for all dietary components. Calibration equations did not capture dependencies on body mass index. We also compared predicted bias in estimated relative risks adjusted using 24HRs as reference instruments with bias when making no adjustment. In disease models with energy and 1 or more nutrient intakes, predicted bias in estimated nutrient relative risks was reduced on average, but bias in the energy risk coefficientwas unchanged.
机译:建议在估计饮食-疾病关联时校准饮食自我报告工具,以调整测量误差。由于可用于校准的生物标记物有限,因此大多数研究者将自我报告(例如24小时召回(24HRs))用作参考工具。我们使用来自验证研究汇总项目的数据评估了24HRs作为校准食物频率问卷(FFQ)的参考工具的性能,其中包括5个使用回收生物标记物的大型验证研究。使用24HR作为参考工具,我们估算了FFQ报告的能量,蛋白质,钾和钠及其密度的衰减因子,与真相的相关性以及校准方程式,并将它们与使用生物标记得出的值进行了比较。基于24HRs,FFQ衰减因子被高估了能量和钠的摄入量,而蛋白质和钾的摄入量则被低估了,营养素的密度被最小化了。基于24HRs的FFQ与真实性的相关性被高估了所有饮食成分。校准方程式未捕获对体重指数的依赖性。我们还比较了使用24HRs作为参考工具调整后的估计相对风险中的预测偏差与不进行调整时的偏差。在能量和养分摄入量大于或等于1的疾病模型中,估计养分相对风险的预测偏差平均减少,但能量风险系数的偏差保持不变。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号