首页> 美国卫生研究院文献>Advanced Pharmaceutical Bulletin >Multivariate Chemometric Assisted Analysis of Metformin Hydrochloride Gliclazide and Pioglitazone Hydrochloride in Bulk Drug and Dosage Forms
【2h】

Multivariate Chemometric Assisted Analysis of Metformin Hydrochloride Gliclazide and Pioglitazone Hydrochloride in Bulk Drug and Dosage Forms

机译:散装药物和剂型的盐酸二甲双胍格列齐特和盐酸吡格列酮的多化学计量学辅助分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: In this work a numerical method, based on the use of spectrophotometric data coupled to partial least squares (PLS) regression and net analyte preprocessing combined with classical least square (NAP/CLS) multivariate calibration, is reported for the simultaneous determination of metformin hydrochloride (MET), gliclazide (GLZ) and pioglitazone hydrochloride (PIO) in synthetic samples and combined commercial tablets. >Methods: Spectra of MET, GLZ and PIO were recorded at concentrations within their linear ranges (5-25 µg/ml, 0.5-8 µg/ml and 0.5-3 µg/ml respectively) and were used to compute a total of 25 synthetic mixtures involving 15 calibration and 10 validation sets between wavelength range of 200 and 400 nm in 0.1N HCl. The suitability of the models was decided on the basis of root mean square error (RMSE) values of calibration and validation data. >Results: The analytical performances of these chemometric methods were characterized by relative prediction errors and recovery studies (%) and were compared with each other. These two methods were successfully applied to pharmaceutical formulation, tablet, with no interference with excipients as indicated by the recovery study results. Mean recoveries of the commercial formulation set together with the figures of merit (calibration sensitivity, selectivity, limit of detection, limit of quantification etc.) were estimated. >Conclusion: The proposed methods are simple, rapid and can be easily used as an alternative analysis tool in the quality control of drugs and formulation.
机译:>目的:在这项工作中,一种基于分光光度数据结合偏最小二乘(PLS)回归和净分析物预处理结合经典最小二乘(NAP / CLS)多元校准的数值方法是报道了同时测定合成样品和市售片剂中盐酸二甲双胍(MET),格列齐特(GLZ)和盐酸吡格列酮(PIO)的含量。 >方法:记录MET,GLZ和PIO的光谱在其线性范围内(分别为5-25 µg / ml,0.5-8 µg / ml和0.5-3 µg / ml)的浓度并使用以计算总共25种合成混合物,包括在0.1N HCl中200至400 nm波长范围内的15个校准和10个验证集。模型的适用性是根据校准和验证数据的均方根误差(RMSE)值确定的。 >结果:这些化学计量学方法的分析性能通过相对预测误差和回收率研究(%)进行了表征,并进行了比较。回收率研究结果表明,这两种方法已成功应用于药物制剂片剂,且不干扰赋形剂。估算了市售制剂的平均回收率和品质因数(校准灵敏度,选择性,检测限,定量限等)。 >结论:所提出的方法简单,快速,可轻松用作药物和制剂质量控制中的替代分析工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号