首页> 美国卫生研究院文献>Allergy Rhinology >Piezoelectric sensing: Evaluation for clinical investigation of deviated nasal septum
【2h】

Piezoelectric sensing: Evaluation for clinical investigation of deviated nasal septum

机译:压电传感:鼻中隔偏斜的临床研究评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Noninvasive objective evaluation of nasal airflow is one of the important clinical aspects. The developed polyvinylidene fluoride (PVDF) sensor enables measurement of airflow through each side of the nose using its piezoelectric property. This study was designed to evaluate the diagnostic capability of the PVDF sensor in assessing the deviated nasal septum (DNS). PVDF nasal sensor uses its piezoelectric property to measure the peak-to-peak amplitude (Vp-p) of nasal airflow in both of the nostrils: right nostril (RN) and left nostril (LN), separately and simultaneously. We have compared the results of PVDF nasal sensor, visual analog scale (VAS), and clinician scale for 34 DNS patients and 28 healthy controls. Additionally, the results were further analyzed by receiver operating characteristic curve and correlation between PVDF nasal sensor and VAS in detecting DNS. We found a significant difference in the peak-to-peak amplitude values of the test group and the control group. The correlation between the PVDF nasal sensor measurements and VAS (RN and LN combined) for test group was statistically significant (−0.807; p < 0.001). Sensitivity and specificity of the PVDF nasal sensor measurements in the detection of DNS (RN and LN combined) was 85.3 and 74.4%, respectively, with optimum cutoff value ≤0.34 Vp-p. The developed PVDF nasal sensor is noninvasive and requires less patient efforts. The sensitivity and specificity of the PVDF nasal sensor are reliable. According to our findings, we propose that the said PVDF nasal sensor can be used as a new diagnostic tool to evaluate the DNS in routine clinical practice.
机译:鼻气流的非侵入性客观评估是重要的临床方面之一。研发的聚偏二氟乙烯(PVDF)传感器能够利用其压电特性测量流经鼻子每一侧的气流。本研究旨在评估PVDF传感器在评估鼻中隔偏斜(DNS)时的诊断能力。 PVDF鼻传感器利用其压电特性分别和同时测量两个鼻孔(右鼻孔(RN)和左鼻孔(LN))中鼻腔气流的峰峰值(Vp-p)。我们比较了34例DNS患者和28例健康对照者的PVDF鼻传感器,视觉模拟量表(VAS)和临床医生量表的结果。此外,还通过接收器工作特性曲线以及PVDF鼻传感器和VAS在检测DNS中的相关性进一步分析了结果。我们发现测试组和对照组的峰峰值幅度值存在显着差异。测试组的PVDF鼻传感器测量值与VAS(合并RN和LN)之间的相关性具有统计学意义(-0.807; p <0.001)。在检测DNS(RN和LN结合)时,PVDF鼻传感器测量的灵敏度和特异性分别为85.3%和74.4%,最佳截止值≤0.34Vp-p。研发的PVDF鼻传感器是非侵入性的,不需要患者太多的努力。 PVDF鼻传感器的灵敏度和特异性很可靠。根据我们的发现,我们建议将所述PVDF鼻传感器用作常规临床实践中评估DNS的新诊断工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号