>Background and purpose — With a rapidly increasing population in need of total knee arthroplasty (TKA), there is renewed interest in cost-saving all-polyethylene designs. Differences between metal-backed and all-polyethylene designs in initial component migration assessed by radiostereometric analysis (RSA), a proven predictor for late aseptic loosening, have been scantily reported. The purpose of this study was to compare implant migration and clinical outcomes of all-polyethylene tibial components versus metal-backed trays of similar geometrical shape.>Patients and methods — In this randomized controlled trial, 59 patients received a cemented Triathlon condylar-stabilizing implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed tibial component (n = 30). RSA measurements and clinical scores (the Knee Society Score, Forgotten Joint Score, and Knee Osteoarthritis and Injury Outcome Score) were evaluated at baseline and postoperatively at 3, 12, and 24 months. A linear mixed-effects model was used to analyze the repeated measurements.>Results — A statistically significant difference in mean migration after 2 years was found in favor of the all-polyethylene group, with a mean maximum total point motion of 0.61 mm (95% CI 0.49–0.74) versus 0.81 mm (95% CI 0.68–0.96) for the cemented group (p = 0.03). However, this difference was smaller and not statistically significant after post hoc adjustment for surgeon effect. Both groups showed comparable improvements on all clinical outcome scores over time.>Interpretation — The Triathlon all-polyethylene tibial component showed less migration, suggesting a lower risk of late loosening as compared with its metal-backed counterpart. However, the found surgeon effect warrants further investigation.
机译:>背景和目的-随着需要全膝关节置换术(TKA)的人口快速增长,人们对节省成本的全聚乙烯设计重新产生了兴趣。很少有人报告了通过放射性立体分析(RSA)评估的金属支持的设计和全聚乙烯设计之间在初始组件迁移方面的差异,该事实已被证明是晚期无菌性松动的预测指标。这项研究的目的是比较全聚乙烯胫骨组件与几何形状相似的金属支撑托板的植入物迁移和临床结果。 >患者和方法—在这项随机对照试验中,有59例患者接受了用全聚乙烯(n = 29)或金属支持的胫骨组件(n = 30)固定的铁人三项con突稳定植入物(Stryker,Mahwah,NJ,美国)。在基线时以及术后3、12和24个月评估RSA测量值和临床评分(膝关节评分,被遗忘的关节评分以及膝骨关节炎和损伤结果评分)。结果-使用线性混合效应模型分析重复测量的结果。 >结果-发现全聚乙烯组在2年后的平均迁移率上存在统计学上的显着差异,这有利于全聚乙烯组骨水泥组的运动为0.61 mm(95%CI 0.49–0.74),而运动组为0.81 mm(95%CI 0.68–0.96)(p = 0.03)。但是,在对医生效果进行事后调整之后,这种差异较小,在统计学上不显着。两组随时间的推移在所有临床结局评分上均表现出可比的改善。 >解释-铁人三项全聚乙烯胫骨组件显示出较少的迁移,与金属支持的同伴相比,晚期松弛的风险较低。但是,发现的外科医生效应值得进一步调查。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号