The results of femoropopliteal bypass to the infragenicular popliteal artery, in the absence of suitable saphenous vein have, in the main, been disappointing. We present a new type of composite graft, for use when the distal anastomosis is below the knee, which avoids the potential problems of prosthetic graft alone. The graft consists of a proximal segment of 6 mm expanded PTFE (Gore-Tex; or Impra), anastomosed to transposed non-reversed autologous saphenous vein. Forty-two patients were studied following unilateral, below knee composite femoropopliteal graft surgery for severe claudication or critical ischaemia. Pressure indices were calculated along with intraoperative flow rate, and all patients were followed up at regular intervals to assess graft patency. During the study period three patients died and graft occlusion occurred in a further eight. Analysis of the cumulative patency curve revealed that the majority of occlusions occurred in the first 3 months. The patency at 12 and 18 months was encouraging with values of 84% and 79% respectively. Comparison of pressure indices revealed a significant increase following surgery (P less than 0.001). The postoperative pressure index appeared to predict the grafts likely to occlude and the intraoperative flow rates mirrored a similar trend. Grafts which occluded had a significantly lower pressure index and flow rate (P less than 0.01, P less than 0.002, respectively). Our results suggest that for infragenicular femoropopliteal bypass grafting where full length in-situ vein graft is not possible; a composite graft using PTFE with non-reversed vein is a good alternative.
机译:在没有合适的大隐静脉的情况下,股pop动脉旁路到gen下pop动脉的结果主要令人失望。我们提出了一种新型的复合移植物,用于远端吻合术在膝盖以下时使用,这避免了单独使用人工移植物的潜在问题。移植物由一个6 mm膨胀PTFE(Gore-Tex;或Impra)的近端段组成,吻合到转位的非反向自体隐静脉。对42例单侧膝下复合股pop动脉移植术后严重c行或严重缺血的患者进行了研究。计算压力指数以及术中流速,并定期随访所有患者以评估移植物通畅性。在研究期间,三名患者死亡,另外八名患者发生了移植物阻塞。对累积通畅曲线的分析表明,大多数阻塞发生在头3个月内。 12个月和18个月的通畅率令人鼓舞,分别为84%和79%。压力指数的比较显示,术后明显增加(P小于0.001)。术后压力指数似乎可以预测移植物可能发生阻塞,并且术中流速反映出相似的趋势。堵塞的接枝具有显着较低的压力指数和流速(P分别小于0.01,P小于0.002)。我们的结果表明,对于不可能进行全长原位静脉移植的下gen骨股pop旁路移植术;使用非反向静脉PTFE的复合移植物是一个很好的选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号