首页> 美国卫生研究院文献>Antimicrobial Agents and Chemotherapy >Comparison of radioimmunoassay and enzyme immunoassay methods in determining gentamicin pharmacokinetic parameters and dosages.
【2h】

Comparison of radioimmunoassay and enzyme immunoassay methods in determining gentamicin pharmacokinetic parameters and dosages.

机译:在确定庆大霉素药代动力学参数和剂量时放射免疫法和酶免疫法的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Radioimmunoassay and enzyme immunoassay methods for analysis of serum gentamicin levels have been shown to be comparable. The purpose of this study was to determine if serum concentration-time data from the same patient assayed by radioimmunoassay and enzyme immunoassay would provide the same estimates for half-life, elimination rate constant, distribution volume, drug clearance, and gentamicin dose. A total of 103 pre- and postinfusion serum samples were obtained from 32 patients. The samples were divided and assayed by radioimmunoassay and enzyme immunoassay. Serum concentration-time data were fitted to a one-compartment model, and kinetic calculations were performed using the method of Sawchuk et al. (Clin. Pharmacol. Ther. 21:362-369, 1977). While good correlation was established between the two assay methods, significant (P less than 0.05) mean differences were seen in distribution volume (25%), gentamicin clearance (15%), and half-life (11%), using the quantitative data from both methods. Because of differences noted in these pharmacokinetic parameters, significant differences were also noted in dosage calculations. We conclude that there are differences in the pharmacokinetic parameters obtained using results from the radioimmunoassay and enzyme immunoassay. These differences also translate into significant differences between dosage recommendations when individualization of the gentamicin regimen is attempted.
机译:已证明用于分析庆大霉素水平的放射免疫分析和酶免疫分析方法具有可比性。这项研究的目的是确定通过放射免疫法和酶免疫法测定的同一患者的血清浓度-时间数据是否可以提供相同的半衰期,消除率常数,分布体积,药物清除率和庆大霉素剂量估计值。从32位患者中总共获得了103份输注前后的血清样品。将样品分开并通过放射免疫测定和酶免疫测定进行测定。将血清浓度-时间数据拟合至一室模型,并使用Sawchuk等人的方法进行动力学计算。 (Clin.Pharmacol.Ther.21:362-369,1977)。虽然在两种测定方法之间建立了良好的相关性,但使用定量数据,在分布量(25%),庆大霉素清除率(15%)和半衰期(11%)上发现了显着性差异(P小于0.05)。从这两种方法。由于这些药代动力学参数存在差异,因此在剂量计算中也存在明显差异。我们得出结论,使用放射免疫分析和酶免疫分析的结果获得的药代动力学参数存在差异。当尝试庆大霉素方案的个体化时,这些差异还转化为剂量建议之间的显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号