Quest for a Realistic In Vivo Test Method for Antimicrobial Hand-Rub Agents: Introduction of a Low-Volume Hand Contamination Procedure

机译:寻求抗菌手擦剂的现实体内测试方法:小批量手污染程序的介绍

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A novel method has been developed for the evaluation of alcohol-based hand rubs (ABHR) that employs a hand contamination procedure that more closely simulates the in-use conditions of ABHR. Hands of human subjects were contaminated with 0.2 ml of a concentrated suspension of Serratia marcescens (ATCC 14756) to achieve baseline contamination between 8 and 9 log10 CFU/hand while allowing product to be applied to dry hands with minimal soil load. Evaluation of 1.5 ml of an ABHR gel containing 62% ethanol produced log10 reductions of 2.66 ± 0.96, 2.40 ± 0.50, 2.41 ± 0.61, and 2.33 ± 0.49 (means ± standard deviations) after 1, 3, 7, and 10 successive contamination/product application cycles. In a study comparing this low-volume contamination (LVC) method to ASTM E1174, product dry times were more realistic and log10 reductions achieved by the ABHR were significantly greater when LVC was employed (P < 0.05). These results indicate that a novel low-volume hand contamination procedure, which more closely represents ABHR use conditions, provides more realistic estimates of in-use ABHR efficacies. Based on the LVC method, log10 reductions produced by ABHR were strongly dependent on the test product application volume (P < 0.0001) but were not influenced by the alcohol concentration when it was within the range of 62 to 85% (P = 0.378).
机译:已开发出一种用于评估酒精基手擦(ABHR)的新方法,该方法采用了一种手部污染程序,该程序更紧密地模拟了ABHR的使用条件。用0.2 ml粘质沙雷氏菌浓缩悬浮液(ATCC 14756)污染人类受试者的手,以达到每手8至9 log10 CFU的基线污染,同时允许将产品涂抹到干燥的手上,以最小的土壤负荷。在连续污染1、3、7和10次后,评估1.5 ml含有62%乙醇的ABHR凝胶后,log10降低了2.66±0.96、2.40±0.50、2.41±0.61和2.33±0.49(均值±标准偏差)/产品应用周期。在一项将这种小体积污染(LVC)方法与ASTM E1174进行比较的研究中,使用LVC时,产品干燥时间更为实际,ABHR的log10降低幅度更大(P <0.05)。这些结果表明,一种新颖的小批量手部污染程序,可以更紧密地代表ABHR的使用条件,它可以更实际地估算使用中的ABHR效率。基于LVC方法,ABHR产生的log10减少量在很大程度上取决于测试产品的施用量(P <0.0001),但当酒精浓度在62%至85%之间时则不受醇浓度的影响(P = 0.378)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号