Water samples of various origins were inoculated into a specific coliform-selective lactose broth provided with lipoic (thioctic) acid, and the time evolution of the redox potential of the cultures was monitored during incubation at 41 degrees C by use of gold versus reference electrodes. Positive potential-time responses, i.e., 100-mV potential shifts recorded within 20 h of inoculation, were related to the initial number of fecal coliforms in the broth determined by control enumeration techniques, and the organisms responsible were isolated and identified by conventional procedures. A total of 30 samples of wastewater, 38 of surface water, 553 of groundwater, and 110 of drinking water were tested successively. A total of 240 natural water samples, including 172 groundwater samples, and 1 drinking water sample were found to be positive in the potentiometric test. The majority (i.e., 92.5%) of the relevant potentiometric detection times were shorter than 15 h, and 96% of these could be attributed to Escherichia coli. Fifteen hours corresponded to the limit for detecting 1 E. coli cell per 100 ml of water. About 78% of the potentiometric responses occurring after 15 h were induced by fecal coliforms other than E. coli (Enterobacter cloacae, Klebsiella pneumoniae, and Citrobacter freundii). Calibration curves relating detection times shorter than 15 h to fecal coliform (i.e., E. coli) concentrations were constructed for the natural water samples tested. There were minor variations in the average growth rate of the organisms in the relation to the contamination level of the water tested. The number of false-positive samples in the potentiometric test was equivalent to that of false-negative samples (groundwater or drinking water).
机译:将各种来源的水样品接种到提供了硫辛酸的特定大肠菌素选择性乳糖肉汤中,并通过使用金电极和参比电极在41摄氏度温育期间监测培养物氧化还原电位的时间演变。正电位-时间响应,即接种后20小时内记录的100-mV电位变化与通过对照枚举技术确定的肉汤中粪大肠菌群的初始数量有关,并且通过常规程序分离和鉴定了负责的微生物。依次测试了30个废水样本,38个地表水,553个地下水和110个饮用水。在电位测试中,总共发现240个天然水样品,包括172个地下水样品和1个饮用水样品为阳性。大部分相关电位检测时间(即92.5%)短于15小时,其中96%可归因于大肠杆菌。 15小时对应于每100毫升水检测1个大肠杆菌细胞的极限。 15小时后发生的大约78%的电位反应是由大肠杆菌(粪便泄殖腔肠杆菌,肺炎克雷伯菌和弗氏柠檬酸杆菌)以外的大肠菌群诱导的。对于测试的天然水样品,构建了将检测时间短于15小时的时间与粪便大肠菌(即大肠杆菌)浓度相关的校准曲线。与所测试的水的污染水平有关,生物的平均生长率存在细微的差异。电位测试中假阳性样品的数量等于假阴性样品(地下水或饮用水)的数量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号