首页> 美国卫生研究院文献>Applied and Environmental Microbiology >Interpretation of the Tube Coagulase Test for Identification of Staphylococcus aureus
【2h】

Interpretation of the Tube Coagulase Test for Identification of Staphylococcus aureus

机译:管凝血酶测试法鉴定金黄色葡萄球菌的解释

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The tube coagulase test is a valid means of identifying Staphylococcus aureus, provided that only a firm clot that does not move when the tube is tipped is considered a positive reaction. The widely promulgated interpretation that all degrees of clotting in coagulase plasma are a positive identification of S. aureus was disproved by the use of other tests such as anaerobic glucose fermentation thermonuclease production, and lysostaphin sensitivity. It was found that the source of supply of the coagulase plasma is a factor in the occurrence of false-positive coagulase test results. The use of pig and rabbit plasma in the tube coagulase test is also discussed.
机译:试管凝结酶测试是鉴定金黄色葡萄球菌的有效方法,前提是只有当试管倾斜时不会移动的牢固凝块才被视为阳性反应。广泛发布的解释认为,凝固酶血浆中的所有凝结度都是金黄色葡萄球菌的阳性鉴定,但通过使用其他测试(如厌氧葡萄糖发酵热核酸酶生产和溶葡萄球菌素敏感性)则无法证明这一点。已发现,凝固酶血浆的供应来源是发生假阳性凝固酶测试结果的因素。还讨论了猪和兔血浆在管凝结酶测试中的用途。