首页> 美国卫生研究院文献>Applied and Environmental Microbiology >Detection and Incidence of Escherichia coli on Storage Pen Surfaces of Fishing Trawlers
【2h】

Detection and Incidence of Escherichia coli on Storage Pen Surfaces of Fishing Trawlers

机译:拖网渔船储水笔表面大肠杆菌的检测和发病率

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Six methods for the detection and enumeration of Escherichia coli on the storage pen surfaces of commercial fishing trawlers and in harbor wash water were evaluated. E. coli was found consistently present in Boston harbor water used for washing vessel holds and was detected either in small numbers or not at all on storage pen surfaces. Violet Red Bile Agar as a primary enumeration medium was found ineffective for detection of coliforms because of the nonselective development of large numbers of other gram-negative organisms. The use of E. coli broth at 44.5 C for primary most-probable-number determinations, followed by confirmation of E. coli on Levine Eosine Methylene Blue Agar, appears to offer numerous advantages over more conventional methods of detecting E. coli for survey studies of the fishing industry, where coliform-like organisms result in many false-positive presumptives with other methods.
机译:评估了六种检测和计数商用捕鱼拖网渔船的储水笔表面和港口冲洗水中大肠杆菌的方法。在波士顿港的清洗船舱用水中始​​终存在大肠杆菌,并且在存储笔表面上很少或根本没有检测到大肠杆菌。由于大量其他革兰氏阴性生物的非选择性发育,发现紫红色胆汁琼脂作为主要的计数培养基不能检测大肠菌。在44.5 C下使用大肠杆菌肉汤进行最可能的一次测定,然后在羊血曙红亚甲基蓝琼脂上确认大肠杆菌,这比常规的检测大肠杆菌的调查方法更具优势。在渔业中,大肠菌样生物通过其他方法导致许多假阳性假说。