首页> 美国卫生研究院文献>Arthroplasty Today >Custom titanium sleeve for surgical treatment of mechanically assisted crevice corrosion in the well-fixed noncontemporary stem in total hip arthroplasty
【2h】

Custom titanium sleeve for surgical treatment of mechanically assisted crevice corrosion in the well-fixed noncontemporary stem in total hip arthroplasty

机译:定制的钛合金套筒用于在全髋关节置换术中固定的非当代的茎中进行机械辅助缝隙腐蚀的手术治疗

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Adverse local tissue reaction associated with total hip replacement may occur when mechanically assisted crevice corrosion occurs at metal-metal modular junctions in which at least one of the components is fabricated from cobalt-chromium alloy. Complete removal of components may be associated with significant morbidity; when components are well fixed and in acceptable position, it may be appropriate to consider modular rather than complete revision. We have diagnosed mechanically assisted crevice corrosion in total hip arthroplasty patients with noncontemporary but well-fixed femoral components and found that modular conversion to a ceramic femoral head to remove a source of CoCr corrosion and fretting products was only possible by having a custom titanium sleeve manufactured. Surgical implantation with a revision style Biolox ceramic head (CeramTec, Plochingen, Germany) was then achieved.
机译:当机械辅助缝隙腐蚀发生在金属-金属模块化接合处时,可能发生与全髋关节置换有关的不良局部组织反应,在该接合处,至少一个部件是由钴铬合金制成的。彻底清除成分可能会导致明显的发病率;当组件固定好并处于可接受的位置时,考虑模块化而不是完全修订可能是合适的。我们已经诊断出具有非当代但固定良好的股骨组件的全髋关节置换术患者的机械辅助缝隙腐蚀,并发现只有通过制造定制的钛套才能实现模块化转换为陶瓷股骨头以去除CoCr腐蚀和微动产品的可能。 。然后实现了采用修正型Biolox陶瓷头(德国普洛欣根的CeramTec)的手术植入。

著录项

  • 期刊名称 Arthroplasty Today
  • 作者单位
  • 年(卷),期 2015(1),4
  • 年度 2015
  • 页码 107–110
  • 总页数 4
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 15:57:06

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号