The aim of this study was to compare the new Cochlear Nucleus® Profile with Slim Modiolar Electrode (CI532, Cochlear Ltd., Sidney, Australia) with the previous Contour Advance® (CI512) implant through postoperative residual hearing (RH) threshold shift and telemetry measurements as indirect measures of cochlear trauma. We compared 21 patients implanted with the CI532 and 20 patients implanted with the CI512, matching the 2 groups for age and for hearing loss etiology. All subjects received audiological pure tone average (PTA) calculation pre- and postimplant. Electrode impedance was measured, followed by AutoNRT® to measure and evaluate the Neural Response Telemetry (NRT®) thresholds. Telemetry recordings were made intraoperatively, one month after surgery and one month after activation. The NRT-Ratio was calculated to evaluate full scala tympani (ST) insertion. The results showed a higher number of patients with preserved measurable hearing with the CI532 (10/15; P>0.05) compared to the CI512 (5/14; P<0.05). A significant difference in post-operative low frequency PTA was observed between the two groups. There were no significant differences for telemetry measurements and NRTRatio evaluation of full ST insertion (CI512: 81%; CI532: 95%). A significantly higher number of patients who preserved measurable hearing with the CI532, and a significantly higher post-operative low frequency PTA threshold compared with the CI512 confirmed better RH preservation and lower apical cochlear damage with the CI532. There was a high number of full ST insertions for both electrode arrays. Future studies should investigate the audiological effect of implantation in patients with higher levels of RH, correlating the results with the scalar position, to assess any lesser trauma of the CI532.
机译:这项研究的目的是将新的Cochlear Nucleus ®型材与Slim Modiolar电极(CI532,澳大利亚悉尼的Cochlear Ltd.)与之前的Contour Advance < sup>®(CI512)植入物通过术后残余听力(RH)阈值偏移和遥测测量作为耳蜗创伤的间接测量。我们比较了21例植入CI532的患者和20例植入CI512的患者,将两组患者的年龄和听力损失病因匹配。所有受试者在植入前和植入后均接受听力学纯音平均(PTA)计算。测量电极阻抗,然后测量AutoNRT ®以测量和评估神经响应遥测(NRT ®)阈值。术中,手术后一个月和激活后一个月进行遥测记录。计算NRT比率,以评估完整的scala tympani(ST)插入。结果显示,与CI512(5/14; P <0.05)相比,CI532(10/15; P> 0.05)能够保留可测量听力的患者数量更多。两组之间术后低频PTA有显着差异。完整ST插入的遥测测量和NRTRatio评估没有显着差异(CI512:81%; CI532:95%)。与CI512相比,使用CI532保持可测量的听力的患者明显多,并且术后低频PTA阈值显着更高,这证实了使用CI532可以更好地保留RH,并降低耳蜗尖顶损伤。两个电极阵列都有大量的完整ST插入。未来的研究应调查在较高RH患者中植入的听力学效果,并将结果与​​标量位置相关联,以评估CI532的任何较小创伤。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号