首页> 美国卫生研究院文献>Journal of Ophthalmology >Visual Performance after Bilateral Implantation of a Four-Haptic Diffractive Toric Multifocal Intraocular Lens in High Myopes
【2h】

Visual Performance after Bilateral Implantation of a Four-Haptic Diffractive Toric Multifocal Intraocular Lens in High Myopes

机译:高度植入近视眼的双触觉复曲面复曲面多焦点人工晶状体植入后的视觉性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Background. The vision with diffractive toric multifocal intraocular lenses after cataract surgery in long eyes has not been studied previously. Objectives. To report visual performance after bilateral implantation of a diffractive toric multifocal intraocular lens in high myopes. Methods. Prospective, observational case series to include patients with axial length of ≥26 mm and corneal astigmatism of >1 dioptre who underwent bilateral AT LISA 909M implantation. Postoperative examinations included photopic and mesopic distance, intermediate, and near visual acuity; photopic contrast sensitivity; visual symptoms (0–5); satisfaction (1–5); and spectacle independence rate. Results. Twenty-eight eyes (14 patients) were included. Postoperatively, mean photopic monocular uncorrected distance, intermediate, and near visual acuities (logMAR) were 0.12 ± 0.20 (standard deviation), 0.24 ± 0.16, and 0.29 ± 0.21, respectively. Corresponding binocular values were −0.01 ± 0.14, 0.13 ± 0.12, and 0.20 ± 0.19, respectively. One eye (4%) had one-line loss in vision. Under mesopic condition, intermediate vision and near vision decreased significantly (all P ≤ 0.001). Contrast sensitivity at all spatial frequencies did not improve significantly under binocular condition (all P > 0.05). Median scores for halos, night glare, starbursts, and satisfaction were 0.50, 0.00, 0.00, and 4.25, respectively. Ten patients (71%) reported complete spectacle independence. Conclusions. Bilateral implantation of the intraocular lens in high myopes appeared to be safe and achieved good visual performance and high satisfaction.
机译:背景。此前尚未研究过白内障手术后长视力后方使用复曲面复光多焦点人工晶状体的视力。目标。报告高度近视眼的双侧复曲面复光多焦点人工晶状体植入后的视觉性能。方法。前瞻性观察病例系列包括接受双侧AT LISA 909M植入的轴长≥26mm且角膜散光> 1屈光度的患者。术后检查包括近视和中视距离,中度和近视力;视觉对比敏感度;视觉症状(0-5);满意度(1-5分);和眼镜独立率。结果。包括二十八只眼(14例)。术后平均未矫正的近视单眼,中度和近视力(logMAR)为0.12±0.20(标准差),0.24±0.16和0.29±0.21。相应的双目值分别为-0.01±0.14、0.13±0.12和0.20±0.19。一只眼睛(4%)的视力下降了一线。在中视条件下,中视力和近视力显着降低(所有P≤0.001)。在双目条件下,所有空间频率的对比度灵敏度均未显着改善(所有P> 0.05)。光环,夜间眩光,星暴和满意度的中位数分别为0.50、0.00、0.00和4.25。 10名患者(71%)表示完全独立。结论。在高度近视眼中双眼人工晶状体植入似乎是安全的,并获得了良好的视觉性能和高度满意度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号