摘要

Procedures involving phlebotomy are critical for obtaining diagnostic blood specimens and represent a well known and recognized problem, probably among the most important issues in laboratory medicine. The aim of this report is to show spurious hyperkalemia and hypocalcemia due to inadequate phlebotomy procedure. The diagnostic blood specimens were collected from a male outpatient 45 years old, with no clinical complaints. The tubes drawing order were as follows: i) clot activator and gel separator (serum vacuum tube), ii) K3EDTA, iii) a needleless blood gas dedicated-syringe with 80 I.U. lithium heparin, directly connected to the vacuum tube holder system. The laboratory testing results from serum vacuum tube and dedicated syringe were 4.8 and 8.5 mmol/L for potassium, 2.36 and 1.48 mmol/L for total calcium, respectively. Moreover 0.15 mmol/L of free calcium was observed in dedicated syringe. A new blood collection was performed without K3EDTA tube. Different results were found for potassium (4.7 and 4.5 mmol/L) and total calcium (2.37 and 2.38 mmol/L) from serum vacuum tube and dedicated syringe, respectively. Also free calcium showed different concentration (1.21 mmol/L) in this new sample when compared with the first blood specimen. Based on this case we do not encourage the laboratory managers training the phlebotomists to insert the dedicated syringes in needle-holder system at the end of all vacuum tubes. To avoid double vein puncture the dedicated syringe for free calcium determination should be inserted immediately after serum tubes before EDTA vacuum tubes.
机译:涉及放血的程序对于获得诊断性血液标本至关重要,并且代表了一个众所周知的公认问题,可能是实验室医学中最重要的问题之一。本报告的目的是显示由于静脉切开术操作不当而导致的假性高钾血症和低钙血症。诊断性血液样本采自45岁的男性门诊患者,无临床不适。试管的绘制顺序如下:i)凝块活化剂和凝胶分离器(血清真空管),ii)K3EDTA,iii)80 I.U的无针血气专用注射器。肝素锂,直接连接到真空管固定器系统。血清真空管和专用注射器的实验室测试结果分别为钾的4.8和8.5 mmol / L,总钙的2.36和1.48 mmol / L。此外,在专用注射器中观察到0.15 mmol / L的游离钙。不使用K3EDTA管进行新的血液采集。血清真空管和专用注射器的钾(4.7和4.5 mmol / L)和总钙(2.37和2.38 mmol / L)分别得到不同的结果。与第一份血液样本相比,该新样本中的游离钙浓度也不同(1.21 mmol / L)。基于这种情况,我们不鼓励实验室管理人员培训抽血医生将专用注射器插入所有真空管末端的持针器系统中。为避免两次静脉穿刺,应在血清试管后立即将专用的游离钙测定注射器插入EDTA真空管之前。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号