首页> 美国卫生研究院文献>Biology of Sport >The effect of trial familiarisation on the validity and reproducibility of a field-based self-paced VO2max test
【2h】

The effect of trial familiarisation on the validity and reproducibility of a field-based self-paced VO2max test

机译:熟悉试验对基于现场的自定进度VO2max测试的有效性和可重复性的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The self-paced maximal oxygen uptake (VO2max) test (SPV), which is based on the Borg 6-20 Ratings of Perceived Exertion (RPE) scale, allows participants to self-regulate their exercise intensity during a closed-loop incremental maximal exercise test. As previous research has assessed the utility of the SPV test within laboratory conditions, the purpose to this study was to assess the effect of trial familiarisation on the validity and reproducibility of a field-based, SPV test. In a cross-sectional study, fifteen men completed one laboratory-based graded exercise test (GXT) and three field-based SPV tests. The GXT was continuous and incremental until the attainment of VO2max. The SPV, which was completed on an outdoor 400m athletic track, consisted of five x 2 min perceptually-regulated (RPE11, 13, 15, 17 and 20) stages of incremental exercise. There were no differences in the VO2max reported between the GXT (63.5±10.1 ml·kg-1·min-1) and each SPV test (65.5±8.7, 65.4±7.0 and 66.7±7.7 ml·kg-1·min-1 for SPV1, SPV2 and SPV3, respectively; P>.05). Similar findings were observed when comparing VO2max between SPV tests (P>.05). High intraclass correlation coefficients were reported between the GXT and the SPV, and between each SPV test (≥.80). Although participants ran faster and further during SPV3, a similar pacing strategy was implemented during all tests. This study demonstrated that a field-based SPV is a valid and reliable VO2max test. As trial familiarisation did not moderate VO2max values from the SPV, the application of a single SPV test is an appropriate stand-alone protocol for gauging VO2max.
机译:自定最大摄氧量(VO2max)测试(SPV)基于博格6-20知觉运动评分(RPE)量表,可让参与者在闭环增量最大运​​动中自我调节运动强度测试。由于先前的研究已经评估了SPV测试在实验室条件下的实用性,因此本研究的目的是评估熟悉试验对基于现场SPV测试的有效性和可重复性的影响。在一项横断面研究中,十五名男子完成了一项基于实验室的分级运动测试(GXT)和三项基于现场的SPV测试。 GXT是连续不断的,直到达到最大摄氧量为止。 SPV在室外400m运动跑道上完成,由五个x 2分钟的知觉调节(RPE11、13、15、17和20)增量运动组成。 GXT(63.5±10.1 ml·kg -1 ·min -1 )和每次SPV测试之间的最大摄氧量无差异(65.5±8.7,65.4± SPV1,SPV2和SPV3分别为7.0和66.7±7.7 ml·kg -1 ·min -1 ; P> .05)。比较SPV测试之间的最大摄氧量(P> .05)时,观察到相似的结果。据报道,GXT和SPV之间以及每次SPV测试之间存在较高的类内相关系数(≥.80)。尽管参与者在SPV3中跑得更快,更远,但在所有测试中都采用了类似的步调策略。这项研究表明,基于现场的SPV是有效且可靠的VO2max测试。由于试验的熟悉程度并未降低SPV的VO2max值,因此,单个SPV测试的应用是测量VO2max的适当独立协议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号