首页> 美国卫生研究院文献>BioMedical Engineering OnLine >Performance assessment in brain-computer interface-based augmentative and alternative communication
【2h】

Performance assessment in brain-computer interface-based augmentative and alternative communication

机译:基于脑机接口的补充和替代交流中的性能评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A large number of incommensurable metrics are currently used to report the performance of brain-computer interfaces (BCI) used for augmentative and alterative communication (AAC). The lack of standard metrics precludes the comparison of different BCI-based AAC systems, hindering rapid growth and development of this technology. This paper presents a review of the metrics that have been used to report performance of BCIs used for AAC from January 2005 to January 2012. We distinguish between Level 1 metrics used to report performance at the output of the BCI Control Module, which translates brain signals into logical control output, and Level 2 metrics at the Selection Enhancement Module, which translates logical control to semantic control. We recommend that: (1) the commensurate metrics Mutual Information or Information Transfer Rate (ITR) be used to report Level 1 BCI performance, as these metrics represent information throughput, which is of interest in BCIs for AAC; 2) the BCI-Utility metric be used to report Level 2 BCI performance, as it is capable of handling all current methods of improving BCI performance; (3) these metrics should be supplemented by information specific to each unique BCI configuration; and (4) studies involving Selection Enhancement Modules should report performance at both Level 1 and Level 2 in the BCI system. Following these recommendations will enable efficient comparison between both BCI Control and Selection Enhancement Modules, accelerating research and development of BCI-based AAC systems.
机译:当前,大量不可度量的指标用于报告用于增强和交替通信(AAC)的脑机接口(BCI)的性能。缺乏标准指标,无法比较基于BCI的不同AAC系统,从而阻碍了该技术的快速发展。本文介绍了从2005年1月到2012年1月用于报告用于AAC的BCI的性能的度量标准的回顾。我们区分了用于报告BCI控制模块输出的性能的1级度量标准,该水平用于翻译大脑信号。到逻辑控制输出中,以及在“选择增强模块”处的2级度量标准中,将逻辑控制转换为语义控制。我们建议:(1)使用相互称呼的相互信息或信息传输速率(ITR)度量来报告1级BCI性能,因为这些度量标准代表信息吞吐量,这是AAC的BCI所关注的; 2)BCI-Utility指标可用于报告2级BCI性能,因为它能够处理所有当前提高BCI性能的方法; (3)这些指标应辅以每个独特的BCI配置所特有的信息; (4)涉及选择增强模块的研究应报告BCI系统在1级和2级的绩效。遵循这些建议将使BCI控制和选择增强模块之间的有效比较成为可能,从而加速了基于BCI的AAC系统的研发。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号