Comparative study of the imaging contrasts of Mueller matrix derived parameters between transmission and backscattering polarimetry

机译:透射和反向散射偏振法中Mueller矩阵导出参数的成像对比度的比较研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Mueller matrix polarimetry is a potentially powerful tool for biomedical diagnosis. Recently, the transmission Mueller matrix microscope and backscattering Mueller matrix endoscope were developed and applied to various pathological samples. However, a comparative study of imaging contrasts of Mueller matrix derived parameters between transmission and backscattering measurements is still needed to help decide which information obtained from transmission Mueller matrix microscope can be directly applied to in vivo Mueller matrix imaging. Here, to compare the imaging contrasts of Mueller matrix derived parameters between transmission and backscattering polarimetry, we measure porcine liver tissue samples and human breast carcinoma tissue specimens. The experiments and corresponding Monte Carlo stimulation results demonstrate that the backscattering and transmission retardance-related Mueller matrix parameters have very similar contrasts to characterize the anisotropic and isotropic structures of pathological tissues, meaning that the conclusions made from Mueller matrix microscopic imaging based on retardance can also be helpful to guide the in situ backscattering Mueller matrix polarimetric diagnosis. However, the values and contrasts of depolarization-related Mueller matrix parameters have some differences between transmission and backscattering polarimetry.
机译:Mueller矩阵极化仪是用于生物医学诊断的潜在强大工具。近来,透射型Mueller矩阵显微镜和后向散射Mueller矩阵内窥镜被开发并应用于各种病理学样品。但是,仍然需要对透射和反向散射测量之间Mueller矩阵得出的参数的成像对比度进行比较研究,以帮助确定从透射Mueller矩阵显微镜获得的哪些信息可以直接应用于体内Mueller矩阵成像。在这里,为了比较透射和反向散射极化分析之间Mueller矩阵得出的参数的成像对比,我们测量了猪肝组织样本和人乳腺癌组织样本。实验和相应的蒙特卡罗刺激结果表明,与反向散射和透射延迟相关的Mueller矩阵参数具有非常相似的对比,以表征病理组织的各向异性和各向同性结构,这意味着基于延迟的Mueller矩阵显微成像得出的结论也可以有助于指导原位反向散射Mueller矩阵极化诊断。但是,与去极化相关的Mueller矩阵参数的值和对比度在透射偏振法和反向散射偏振法之间存在一些差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号