首页> 美国卫生研究院文献>Journal of Pharmaceutical Analysis >Validation and application by HPLC for simultaneous determination of vitexin-2″-O-glucoside vitexin-2″-O-rhamnoside rutin vitexin and hyperoside
【2h】

Validation and application by HPLC for simultaneous determination of vitexin-2″-O-glucoside vitexin-2″-O-rhamnoside rutin vitexin and hyperoside

机译:HPLC的验证和应用可同时测定vitexin-2 -O-葡萄糖苷vitexin-2 -O-鼠李糖苷芦丁vitexin和高丝苷

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A simple, precise, and rapid high-performance liquid chromatographic method was developed and validated for the simultaneous determination of vitexin-2″-O-glucoside, vitexin-2″-O-rhamnoside, rutin, vitexin, and hyperoside. The HPLC separation was performed using a Shim-pack VP-ODS C18 column (250 mm×4.6 mm i.d., 5 μm) with the isocratic mobile phase consisting of tetrahydrofuran/ acetonitrile/0.05% phosphoric acid solution (20:3:77, v/v/v), and the flow rate was set at 1.0 mL/min. UV detection was carried out at a wavelength of 360 nm and the whole analysis took 25 min. The method was linear in the range of 4.12–206.00 μg/mL for vitexin-2″-O-glucoside, 4.05–202.50 μg/mL for vitexin-2″-O-rhamnoside, 1.64–82.00 μg/mL for rutin, 1.74–87.00 μg/mL for vitexin, and 1.41–70.60 μg/mL for hyperoside with the correlation coefficient for each analyte more than 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.6 and 2 ng for vitexin-2″-O-glucoside, 0.6 and 2 ng for vitexin-2″-O-rhamnoside, 0.3 and 1 ng for rutin, 1 and 3 ng for vitexin, and 0.5 and 2 ng for hyperoside, respectively. Intra- and inter-day precision and accuracy (RSD) were less than 3%. The developed HPLC method was successfully applied to the analysis of five flavonoids in hawthorn leaves, hawthorn fruits, and the preparations containing hawthorn leaves or fruits.
机译:开发了一种简单,精确,快速的高效液相色谱方法,并进行了同时测定vitexin-2” -O-葡糖苷,vitexin-2” -O-鼠李糖苷,芦丁,vitexin和hyperoside的验证。使用Shim-pack VP-ODS C18色谱柱(250mm×4.6mm内径,5μm)进行HPLC分离,等度流动相由四氢呋喃/乙腈/0.05%磷酸溶液(20:3:77,v / v / v),流速设置为1.0 mL / min。紫外检测是在360nm的波长下进行的,整个分析需要25分钟。该方法在vitexin-2″ -O-鼠李糖苷为4.12–206.00μg / mL范围内,对于vitexin-2″ -O-鼠李糖苷为4.05–202.50μg / mL,对于芦丁为1.64-82.00μg/ mL,范围为线性。葡萄黄素为–87.00μg/ mL,高脂苷为1.41–70.60μg/ mL,每种分析物的相关系数均大于0.998。 vitexin-2″ -O-鼠李糖苷的检出限(LOD)和定量限(LOQ)分别为0.6和2ng,vitinin-2″ -O-鼠李糖苷的检出限为0.6和2ng,芦丁为0.3和1ng。 Vitexin分别为1和3 ng,高脂苷分别为0.5和2 ng。日内和日间精度和准确度(RSD)不到3%。所开发的HPLC方法已成功地用于分析山楂叶,山楂果实以及含有山楂叶或果实的制剂中的5种类黄酮。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号