首页> 美国卫生研究院文献>Biomedical Optics Express >Determination of reference values for optical properties of liquid phantoms based on Intralipid and India ink
【2h】

Determination of reference values for optical properties of liquid phantoms based on Intralipid and India ink

机译:基于Intralipid和印度墨水确定液体体模光学特性的参考值

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A multi-center study has been set up to accurately characterize the optical properties of diffusive liquid phantoms based on Intralipid and India ink at near-infrared (NIR) wavelengths. Nine research laboratories from six countries adopting different measurement techniques, instrumental set-ups, and data analysis methods determined at their best the optical properties and relative uncertainties of diffusive dilutions prepared with common samples of the two compounds. By exploiting a suitable statistical model, comprehensive reference values at three NIR wavelengths for the intrinsic absorption coefficient of India ink and the intrinsic reduced scattering coefficient of Intralipid-20% were determined with an uncertainty of about 2% or better, depending on the wavelength considered, and 1%, respectively. Even if in this study we focused on particular batches of India ink and Intralipid, the reference values determined here represent a solid and useful starting point for preparing diffusive liquid phantoms with accurately defined optical properties. Furthermore, due to the ready availability, low cost, long-term stability and batch-to-batch reproducibility of these compounds, they provide a unique fundamental tool for the calibration and performance assessment of diffuse optical spectroscopy instrumentation intended to be used in laboratory or clinical environment. Finally, the collaborative work presented here demonstrates that the accuracy level attained in this work for optical properties of diffusive phantoms is reliable.
机译:已经建立了一个多中心研究,以基于Intralipid和India墨水在近红外(NIR)波长下准确表征扩散液体体模的光学特性。来自六个国家的九个研究实验室采用不同的测量技术,仪器设置和数据分析方法,以最佳方式确定了用两种化合物的普通样品制备的扩散稀释液的光学性质和相对不确定度。通过使用合适的统计模型,确定了三个近红外波长的印度墨水固有吸收系数和脂内固有减少散射系数(-20%)的综合参考值,其不确定性约为2%或更好,具体取决于所考虑的波长,和1%。即使在本研究中,我们着眼于特定批次的印度墨水和Intralipid,此处确定的参考值也代表了制备具有精确定义的光学特性的扩散液体体模的坚实而有用的起点。此外,由于这些化合物的现成可用性,低成本,长期稳定性和批次间可重复性,它们为用于实验室或实验室的漫射光谱仪器的校准和性能评估提供了独特的基础工具。临床环境。最后,这里提出的协作工作表明,在这项工作中,对于扩散体模的光学特性所达到的准确性水平是可靠的。

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号