首页> 美国卫生研究院文献>Biomedical Optics Express >A comparison of Doppler optical coherence tomography methods
【2h】

A comparison of Doppler optical coherence tomography methods

机译:多普勒光学相干断层扫描方法的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract: We compare, in detail, the phase-resolved color Doppler (PRCD), phase-resolved Doppler variance (PRDV) and intensity-based Doppler variance (IBDV) methods. All the methods are able to quantify flow speed when the flow rate is within a certain range, which is dependent on the adjacent A-line time interval. While PRCD is most sensitive when the flow direction is along the probing beam, PRDV and IBDV can be used to measure the flow when the flow direction is near perpendicular to the probing beam. However, the values of PRDV and IBDV are Doppler angle-dependent when the Doppler angle is above a certain threshold. The sensitivity of all the methods can be improved by increasing the adjacent A-line time interval while still maintaining a high sampling density level. We also demonstrate for the first time, to the best of our knowledge, high resolution inter-frame PRDV method. In applications where mapping vascular network such as angiogram is more important than flow velocity quantification, IBDV and PRDV images show better contrast than PRCD images. The IBDV and PRDV show very similar characteristics and demonstrate comparable results for vasculature mapping. However, the IBDV is less sensitive to bulk motion and with less post-processing steps, which is preferred for fast data processing situations. In vivo imaging of mouse brain with intact skull and human skin with the three methods were demonstrated and the results were compared. The IBDV method was found to be able to obtain high resolution image with a relative simple processing procedure.
机译:摘要:我们详细比较了相位分辨彩色多普勒(PRCD),相位分辨多普勒方差(PRDV)和基于强度的多普勒方差(IBDV)方法。当流速在一定范围内时,所有方法都可以量化流速,该范围取决于相邻的A线时间间隔。当流动方向沿着探测光束时,PRCD最敏感,而当流动方向接近垂直于探测光束时,PRDV和IBDV可用于测量流量。但是,当多普勒角度高于某个阈值时,PRDV和IBDV的值取决于多普勒角度。通过增加相邻的A线时间间隔,同时仍保持较高的采样密度水平,可以提高所有方法的灵敏度。据我们所知,我们还首次演示了高分辨率帧间PRDV方法。在绘制血管网络(例如血管造影图)比流速量化更重要的应用中,IBDV和PRDV图像显示出比PRCD图像更好的对比度。 IBDV和PRDV具有非常相似的特征,并显示出可比较的脉管系统结果。但是,IBDV对整体运动较不敏感,并且具有较少的后处理步骤,这对于快速数据处理情况是首选。用三种方法对完整的颅骨和人皮肤的小鼠大脑进行了体内成像,并对结果进行了比较。发现IBDV方法能够以相对简单的处理过程获得高分辨率图像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号