首页> 美国卫生研究院文献>Biomedical Optics Express >Signal attenuation and box-counting fractal analysis of optical coherence tomography images of arterial tissue
【2h】

Signal attenuation and box-counting fractal analysis of optical coherence tomography images of arterial tissue

机译:动脉组织光学相干断层扫描图像的信号衰减和计数分形分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The sensitivity of optical coherence tomography images to sample morphology is tested by two methods. The first method estimates the attenuation of the OCT signal from various regions of the probed tissue. The second method uses a box-counting algorithm to calculate the fractal dimensions in the regions of interest identified in the images. Although both the attenuation coefficient as well as the fractal dimension correlate very well with the anatomical features of the probed samples; the attenuation method provides a better sensitivity. Two types of samples are used in this study: segments of arteries collected from atherosclerosis–prone Watanabe rabbits (WHHL-MI) and healthy segments of porcine coronary arteries.
机译:光学相干断层扫描图像对样品形态的敏感性通过两种方法进行测试。第一种方法估计来自被探测组织各个区域的OCT信号的衰减。第二种方法使用盒计数算法来计算图像中标识的感兴趣区域中的分形维数。尽管衰减系数和分形维数都与被探测样品的解剖特征非常相关;衰减方法提供了更好的灵敏度。在这项研究中使用了两种类型的样本:从动脉粥样硬化倾向渡边兔(WHHL-MI)收集的动脉段和猪冠状动脉的健康段。