The vegetable kingdom is a wide source of a diverse variety of enzymes with broad biotechnological applications. Among the main classes of plant enzymes, the polyphenol oxidases, which convert phenolic compounds to the related quinones, have been successfully used for biosensor development. The oxidation products from such enzymes can be electrochemically reduced, and the sensing is easily achieved by amperometric transducers. In this work, the polyphenoloxidases were extracted from jurubeba (Solanum paniculatum L.) fruits, and the extract was used to construct a carbon paste-based biosensor for pharmaceutical analysis and applications. The assay optimization was performed using a 0.1 mM catechol probe, taking into account the amount of enzymatic extract (50 or 200 μL) and the optimum pH (3.0 to 9.0) as well as some electrochemical differential pulse voltammetric (DPV) parameters (e.g., pulse amplitude, pulse range, pulse width, scan rate). Under optimized conditions, the biosensor was evaluated for the quantitative determination of acetaminophen, acetylsalicylic acid, methyldopa, and ascorbic acid. The best performance was obtained for acetaminophen, which responded linearly in the range between 5 and 245 μM (R = 0.9994), presenting a limit of detection of 3 μM and suitable repeatability ranging between 1.52% and 1.74% relative standard deviation (RSD).
机译:植物界是具有广泛生物技术应用的多种酶的广泛来源。在植物酶的主要类别中,将酚类化合物转化为相关醌的多酚氧化酶已成功用于生物传感器的开发。来自此类酶的氧化产物可以被电化学还原,并且通过安培传感器容易地实现感测。在这项工作中,从枣木(Solanum paniculatum L.)果实中提取了多酚氧化酶,并将提取物用于构建基于碳糊的生物传感器,用于药物分析和应用。考虑到酶提取物的量(50或200μL)和最佳pH(3.0至9.0)以及一些电化学差分脉冲伏安(DPV)参数(例如,脉冲幅度,脉冲范围,脉冲宽度,扫描速率)。在最佳条件下,对生物传感器进行了评估,以定量测定对乙酰氨基酚,乙酰水杨酸,甲基多巴和抗坏血酸。对乙酰氨基酚的最佳性能在5至245μM(R = 0.9994)范围内线性响应,检出限为3μM,相对标准偏差(RSD)在1.52%至1.74%之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号