The detection of myoglobin (Myo), cardiac troponin I (cTnI), creatine kinase-MB (CK-MB), and b-type natriuretic peptide (BNP) plays a vital role in diagnosing cardiovascular diseases. Here we present single site-specific polyaniline (PANI) nanowire biosensors that can detect cardiac biomarkers such as Myo, cTnI, CK-MB, and BNP with ultra-high sensitivity and good specificity. Using single PANI nanowire-based biosensors integrated with microfluidic channels, very low concentrations of Myo (100 pg/mL), cTnI (250 fg/mL), CK-MB (150 fg/mL), and BNP (50 fg/mL) were detected. The single PANI nanowire-based biosensors displayed linear sensing profiles for concentrations ranging from hundreds (fg/mL) to tens (ng/mL). In addition, devices showed a fast (few minutes) response satisfying respective reference conditions for Myo, cTnI, CK-MB, and BNP diagnosis of heart failure and for determining the stage of the disease. This single PANI nanowire-based biosensor demonstrated superior biosensing reliability with the feasibility of label free detection and improved processing cost efficiency due to good biocompatibility of PANI to monoclonal antibodies (mAbs). Therefore, this development of single PANI nanowire-based biosensors can be applied to other biosensors for cancer or other diseases.
机译:肌红蛋白(Myo),心肌肌钙蛋白I(cTnI),肌酸激酶-MB(CK-MB)和b型利钠肽(BNP)的检测在诊断心血管疾病中起着至关重要的作用。在这里,我们提出了单部位特异性聚苯胺(PANI)纳米线生物传感器,可以超高灵敏度和良好特异性检测心脏生物标志物,如Myo,cTnI,CK-MB和BNP。使用集成了微流体通道的单个基于PANI纳米线的生物传感器,极低浓度的Myo(100 pg / mL),cTnI(250 fg / mL),CK-MB(150 fg / mL)和BNP(50 fg / mL)被检测到。单个基于PANI纳米线的生物传感器显示线性感应曲线,浓度范围从数百(fg / mL)到数十(ng / mL)。此外,设备显示出快速(几分钟)的响应,可满足Myo,cTnI,CK-MB和BNP诊断心力衰竭以及确定疾病阶段的相应参考条件。由于PANI与单克隆抗体(mAb)具有良好的生物相容性,因此这种基于PANI纳米线的单一生物传感器表现出卓越的生物传感可靠性,并具有无标记检测的可行性,并提高了处理成本效率。因此,基于单个PANI纳米线的生物传感器的这一发展可以应用于癌症或其他疾病的其他生物传感器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号