首页> 美国卫生研究院文献>Journal of Pregnancy >Reference Ranges of Amniotic Fluid Index in Late Third Trimester of Pregnancy: What Should the Optimal Interval between Two Ultrasound Examinations Be?
【2h】

Reference Ranges of Amniotic Fluid Index in Late Third Trimester of Pregnancy: What Should the Optimal Interval between Two Ultrasound Examinations Be?

机译:妊娠晚期晚期羊水指数的参考范围:两次超声检查之间的最佳间隔应该是多少?

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background. Amniotic fluid index (AFI) is one of the major and deciding components of fetal biophysical profile and by itself it can predict pregnancy outcome. Very low values are associated with intrauterine growth restriction and renal anomalies of fetus, whereas high values may indicate fetal GI anomalies, maternal diabetes mellitus, and so forth. However, before deciding the cut-off standards for abnormal values for a local population, what constitutes a normal range for specific gestational age and the ideal interval of testing should be defined. Objectives. To establish reference standards for AFI for local population after 34 weeks of pregnancy and to decide an optimal scan interval for AFI estimation in third trimester in low risk antenatal women. Materials and Methods. A prospective estimation of AFI was done in 50 healthy pregnant women from 34 to 40 weeks at weekly intervals. The trend of amniotic fluid volume was studied with advancing gestational age. Only low risk singleton pregnancies with accurately established gestational age who were available for all weekly scan from 34 to 40 weeks were included in the study. Women with gestational or overt diabetes mellitus, hypertensive disorders of the pregnancy, prelabour rupture of membranes, and congenital anomalies in the foetus and those who delivered before 40 completed weeks were excluded from the study. For the purpose of AFI measurement, the uterine cavity was arbitrarily divided into four quadrants by a vertical and horizontal line running through umbilicus. Linear array transabdominal probe was used to measure the largest vertical pocket (in cm) in perpendicular plane to the abdominal skin in each quadrant. Amniotic fluid index was obtained by adding these four measurements. Statistical analysis was done using SPSS software (Version 16, Chicago, IL). Percentile curves (5th, 50th, and 95th centiles) were constructed for comparison with other studies. Cohen's d coefficient was used to examine the magnitude of change at different time intervals. Results. Starting from 34 weeks till 40 weeks, 50 ultrasound measurements were available at each gestational age. The mean (standard deviation) of AFI values (in cms) were 34 W: 14.59 (1.79), 35 W: 14.25 (1.57), 36 W: 13.17 (1.56), 37 W: 12.48 (1.52), 38 W: 12.2 (1.7), and 39 W: 11.37 (1.71). The 5th percentile cut-off was 8.7 cm at 40 weeks. There was a gradual decline of AFI values as the gestational age approached term. Significant drop in AFI was noted at two-week intervals. AFI curve generated from the study varied significantly when compared with already published data, both from India and abroad. Conclusion. Normative range for AFI values for late third trimester was established. Appreciable changes occurred in AFI values as gestation advanced by two weeks. Hence, it is recommended to follow up low risk antenatal women every two weeks after 34 weeks of pregnancy. The percentile curves of AFI obtained from the present study may be used to detect abnormalities of amniotic fluid for our population.
机译:背景。羊水指数(AFI)是胎儿生物物理特征的主要决定性成分之一,它本身可以预测妊娠结局。极低的值与子宫内生长受限和胎儿的肾脏异常有关,而极高的值可能表明胎儿胃肠道异常,母体糖尿病等。但是,在决定当地人群异常值的临界标准之前,应确定特定胎龄的正常范围和理想的检测间隔。目标。为妊娠34周后的当地人群建立AFI参考标准,并确定低危产前妇女在妊娠中期AFI估计的最佳扫描间隔。材料和方法。每周间隔34至40周,对50名健康孕妇进行AFI的前瞻性评估。研究羊水量随胎龄的增长趋势。该研究仅包括可准确确定胎龄的低风险单胎妊娠,这些妊娠可在每周34至40周内进行每周一次扫描。患有妊娠或明显糖尿病,妊娠高血压疾病,胎膜早破和胎儿先天性异常的妇女以及在整整40周之前分娩的妇女被排除在研究范围之外。为了进行AFI测量,通过穿过脐带的垂直和水平线将子宫腔任意分为四个象限。线性阵列经腹探头用于测量每个象限中与腹部皮肤垂直的平面中最大的垂直袋(以厘米为单位)。羊水指数是通过将这四个测量值相加得出的。使用SPSS软件(版本16,芝加哥,伊利诺伊州)进行统计分析。绘制了百分位曲线(第5,第50和第95个百分位),以便与其他研究进行比较。科恩的d系数用于检查不同时间间隔的变化幅度。结果。从34周到40周,每个胎龄可进行50次超声测量。 AFI值的平均值(标准偏差)(以cms为单位)为34 W:14.59(1.79),35 W:14.25(1.57),36 W:13.17(1.56),37 W:12.48(1.52),38 W:12.2 (1.7)和39 W:11.37(1.71)。 40周时,第5个百分位数的临界值为8.7 cm。随着胎龄接近足月,AFI值逐渐下降。每两周观察到AFI明显下降。与印度和国外已经发表的数据相比,研究产生的AFI曲线差异很大。结论。建立了妊娠晚期的AFI值的标准范围。随着妊娠提前两周,AFI值发生明显变化。因此,建议在怀孕34周后每两周随访一次低危产前妇女。从本研究中获得的AFI的百分比曲线可用于检测我们人群的羊水异常。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号